SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Pistilli R)
 

Sökning: WFRF:(Pistilli R) > Posterior jaws reha...

Posterior jaws rehabilitated with partial prostheses supported by 4.0 x 4.0 mm or by longer implants: One-year post-loading results from a multicenter randomised controlled trial

Felice, P. (författare)
Checchi, L. (författare)
Barausse, C. (författare)
visa fler...
Pistilli, R. (författare)
Sammartino, G. (författare)
Masi, I. (författare)
Ippolito, D. R. (författare)
Esposito, Marco, 1965 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
visa färre...
 (creator_code:org_t)
2016
2016
Engelska.
Ingår i: European Journal of Oral Implantology. - 1756-2406. ; 9:1, s. 35-45
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To evaluate whether 4.0 x 4.0 mm dental implants could be an alternative to implants at least 8.5 mm long, which were placed in posterior jaws, in the presence of adequate bone volumes. Materials and methods: One hundred and fifty patients with posterior (premolar and molar areas) jaws having at least 12.5 mm bone height above the mandibular canal or 11.5 mm below the maxillary sinus, were randomised according to a parallel group design, in order to receive one to three 4.0 mm-long implants or one to three implants which were at least 8.5 mm-long, at three centres. All implants had a diameter of 4.0 mm. Implants were loaded after 4 months with definitive screw retained prostheses. Patients were followed up to 1-year post-loading and outcome measures were prosthesis and implant failures, any complications and peri-implant marginal bone level changes. Results: Seventy-five patients were randomly allocated to each group. One patient dropped out after the 4-month post-loading evaluation from the long implant group. Up to 1-year post-loading, 3 patients lost one 4.0 mm-long implant each in comparison to 2 patients who lost one long implant each (difference in proportion = 0.013; 95% CI:-0.058 to 0.087; P = 0.506). All failures occurred before loading, the failed implants were replaced and the delivery of two prostheses in each group was delayed for several months (difference in proportion = 0.0004; 95% CI:-0.068 to 0.069; P = 0.685). Three short implant patients experienced three complications versus 2 long implant patients (difference in proportion = 0.013; 95% CI:-0.058 to 0.087; P = 0.506). There were no statistically significant differences in prosthesis failures, implant failures and complications. Patients with short implants lost on average 0.53 mm of peri-implant bone and patients with longer implants lost 0.57 mm. There were no statistically significant differences in bone level changes up to 1 year between short and long implants (mean difference = 0.038 mm; 95% CI:-0.068 to 0.138; P = 0.198). Conclusions: One year after loading 4.0 mm-long implants achieved similar results as 8.5 mm-long or longer implants in posterior jaws, however 5- to 10-year post-loading data are necessary before reliable recommendations can be made.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Nyckelord

short dental implants
posterior jaws
controlled clinical-trial
hydroxyapatite-coated implants.
bone
augmentation
7-mm-long implants
edentulous jaws
wide implants
sinus
lift
follow-up
maxilla
mandibles

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy