SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Appelblad Micael)
 

Search: WFRF:(Appelblad Micael) > Can We Rely on the ...

Can We Rely on the Activated Clotting Time to Measure Heparin Anticoagulation? A Clinical Evaluation of Two ACT Monitors

Nilsson, Samuel (author)
Umeå universitet,Avdelningen för medicin
Appelblad, Micael (author)
Umeå universitet,Avdelningen för medicin
Svenmarker, Staffan (author)
Umeå universitet,Avdelningen för medicin
 (creator_code:org_t)
American Society of Extra-Corporeal Technology, 2020
2020
English.
In: The journal of extra-corporeal technology. - : American Society of Extra-Corporeal Technology. - 0022-1058. ; 52:3, s. 212-217
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The sensitivity to heparin during cardiopulmonary bypass (CPB) is determined by patient-specific characteristics and is assessed by the whole blood activated clotting time (ACT). We aimed to examine reliability measures between two different ACT monitors using Bland-Altman analysis: bias should not exceed 50 ± 50 seconds for measurements performed during CPB or 10 ± 10 seconds before and after CPB. The ACT response should be linear in relation to the concentration of heparin in plasma. Twenty patients (n = 20) aged 20-80 years and admitted for coronary artery bypass surgery were enrolled to this clinical observational study. ACT values and antifactor Xa were sampled: 1) before induction of anesthesia, 2) after heparin bolus, 3) during CPB at the start of rewarming, 4) at weaning from CPB, and 5) after heparin reversal. The evaluation comprised the Hemostasis Management System Plus™ (HMS, Medtronic Inc., Minneapolis, MN) and i-STAT™ (Abbott, Point of Care Inc., Princeton, NJ). Bias for the HMS Plus™ vs. i-STAT™ was +105 ± 119 seconds for measurements during CPB and +2.8 ± 11.7 seconds before and after CPB. Associated limits of agreement for the observed bias were ±235 and ±23 seconds, respectively. Inter-device correlation of ACT values was .46 (p < .001) during CPB; otherwise .48 (p = .02). Both devices produced ACT values unrelated (<10%) to the measured heparin concentration. The use of multivariable regression analysis demonstrated an independent association between the ACT measurement and hematocrit, however, not with the plasma concentration of heparin. ACT monitors demonstrate unacceptable bias differences, combined with wide limits of agreement. The ACT response correlated with hematocrit, but not with the actual heparin concentration.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Keyword

activated clotting time
anticoagulation
cardiopulmonary bypass
heparin and heparin concentration
point of care

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Nilsson, Samuel
Appelblad, Micae ...
Svenmarker, Staf ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Cardiac and Card ...
Articles in the publication
The journal of e ...
By the university
Umeå University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close