245 | 1 0 | a Soft textile electrodes for EEG monitoring |
264 | 1 | b IEEE Engineering in Medicine and Biology Society,c 2010 |
338 | a electronic2 rdacarrier | |
500 | a © 2010 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. QC 20120206 | |
520 | a There is a need for long term monitoring of the brain during intensive care. This is e.g. the case for newborn babies that have been exposed to hypoxia during delivery. Electroencephalography (EEG) is the technique of choice. To get a clear and detailed view of the brain activity a large number of EEG electrodes should be used. Applying traditional electrodes one by one is a time-consuming and technically demanding work and therefore electrode caps are sometimes used. The existing caps have however been found to be suboptimal for long term monitoring because they may induce too high a pressure on the scalp of the babies. We have tested three different types of textile electrodes with regard to their potential use for EEG monitoring. The results show that soft conducting textile materials can indeed be used for EEG monitoring. | |
650 | 7 | a TEKNIK OCH TEKNOLOGIERx Medicinteknikx Medicinsk laboratorie- och mätteknik0 (SwePub)206012 hsv//swe |
650 | 7 | a ENGINEERING AND TECHNOLOGYx Medical Engineeringx Medical Laboratory and Measurements Technologies0 (SwePub)206012 hsv//eng |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicin0 (SwePub)3022 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Clinical Medicine0 (SwePub)3022 hsv//eng |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Neurologi0 (SwePub)302072 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Neurology0 (SwePub)302072 hsv//eng |
653 | a biomedical electrodes | |
653 | a electroencephalography | |
653 | a patient care | |
653 | a patient monitoring | |
653 | a textiles | |
653 | a EEG monitoring | |
653 | a brain activity | |
653 | a electrode caps | |
653 | a hypoxia | |
653 | a intensive care | |
653 | a long term monitoring | |
653 | a soft conducting textile materials | |
653 | a soft textile electrodes | |
700 | 1 | a Seoane, Fernando,d 1976-4 aut |
700 | 1 | a Thordstein, Magnusu Salhgrenska University Hospital,Institution for CLinical Neurophysiology4 aut |
710 | 2 | a University of Boråsb School of Engineering4 org |
856 | 4 | u http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=5687755y IEEEXplore |
856 | 4 | u https://kth.diva-portal.org/smash/get/diva2:489156/FULLTEXT01.pdfx primaryx Raw objecty fulltext:print |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-74138 |
856 | 4 8 | u https://doi.org/10.1109/ITAB.2010.5687755 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.