SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Ring Lena)
 

Sökning: WFRF:(Ring Lena) > Communication analy...

Communication analysis in oncology care : Performance of a combination of a content analysis system and a global scale

Fagerlind, Hanna (författare)
Uppsala universitet,Institutionen för farmaci
Bergström, Ida (författare)
Uppsala universitet,Institutionen för farmaci
Kettis, Åsa (författare)
Uppsala universitet,Institutionen för farmaci
visa fler...
Velikova, Galina (författare)
Glimelius, Bengt (författare)
Uppsala universitet,Enheten för onkologi
Ring, Lena (författare)
Uppsala universitet,Institutionen för farmaci
visa färre...
 (creator_code:org_t)
2010-07-28
2011
Engelska.
Ingår i: Psycho-Oncology. - : Wiley. - 1057-9249 .- 1099-1611. ; 20:9, s. 992-1000
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective: The aim was to assess the feasibility and reliability of Velikova's Content Analysis System (VCAS) and the Medical Interaction Process System (MIPS) global scale for evaluation of communication in oncology care.Methods: Seventy routine physician consultations with gastro-intestinal (GI) cancer patients were audio-recorded. Two coders applied VCAS and MIPS global scale to the consultations. VCAS captures aspects of communication like symptoms, side effects, functional issues (e.g. emotional, social, physical), health-related quality of life and medical decision making. MIPS global scale measures the total impression of the consultation, e.g. patient centredness and psychosocial focus.Results: In total, 61 of 70 consultations were coded. The coding took twice the consultations' actual durations in minutes for VCAS. The time for coding MIPS global scale equalled the consultations length. However, the coder had then listened to the consultation twice before, coding for VCAS. Cohen's kappa for all aspects measured by VCAS varied between 0.20 and 1, mean 0.80. One category (Info on test) had a kappa of 0.20, the other categories were all above 0.60. Weighted Kappa for MIPS global scale varied between 0.25 and 0.73, mean 0.42.Conclusions: VCAS and MIPS global scale is a feasible combination of tools for evaluating patient-physician communication regarding content, medical decision making and global aspects of communication. VCAS showed high reliability. The MIPS global scale showed lower reliability, due to its sensitivity to the individual coders' unique values, common for all global scales. Further development of the combination of content and global instruments would be valuable.

Nyckelord

oncology
cancer
patient-physician communication
content analysis systems
clinical practice

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy