Experimental Investigation of the Influence of Flow Obstacles on Post-Dryout Heat Transfer in an Annulus

  • Artikel/kapitelEngelska2009

Förlag, utgivningsår, omfång ...

  • NEW YORK :AMER SOC MECHANICAL ENGINEERS,2009
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:kth-29197
  • https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-29197URI
  • https://doi.org/10.1115/ICONE17-75284DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:kon swepub-publicationtype

Anmärkningar

  • QC 20110201
  • This paper describes the experimental setup, instrumentation and procedures which have been developed in the thermal-hydraulic laboratory at the Royal Institute of Technology (KTH), Stockholm, Sweden, to perform new post-dryout heat transfer investigations in an annulus with flow obstacles. Previous investigations performed in the same laboratory indicated that flow obstacles had a considerable influence on the post-CHF heat transfer. The measured heat transfer enhancement was significantly under-predicted by existing models. However, the net effect of obstacles could not be deduced from the measurements, since reference - obstacle-free measurements- had not been performed. In addition, the number of thermocouples that could be installed inside the heated rod was limited to 8. These deficiencies have been removed in the current approach. Firstly, the present design of the test section allows for measurements both with and without flow obstacles. In this way the net effect of the obstacles will be captured. Secondly, a newly developed technique allowed the installation of 40 thermocouples inside of the heated rod. An additional 40 thermocouples have been installed on the external wall of the heated tube. Therefore, a significant improvement of the accuracy of measurements can be expected. The present arrangement of instrumentation is suitable to perform measurements of heat transfer under both steady-state and transient conditions.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Anglart, HenrykKTH,Reaktorteknologi(Swepub:kth)u13dqfg8 (författare)
  • Hedberg, StellanKTH,Reaktorteknologi(Swepub:kth)u1fx6rs6 (författare)
  • Rydström, StefanKTH,Reaktorteknologi(Swepub:kth)u1wkfhc0 (författare)
  • KTHReaktorteknologi (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:ICONE 17NEW YORK : AMER SOC MECHANICAL ENGINEERS, s. 277-2869780791843536

Internetlänk

Hitta via bibliotek

  • ICONE 17 (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Anghel, Ionut Gh ...
Anglart, Henryk
Hedberg, Stellan
Rydström, Stefan
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Energiteknik
Artiklar i publikationen
ICONE 17
Av lärosätet
Kungliga Tekniska Högskolan

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy