SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:2101 6275 OR L773:2100 014X OR L773:9782759819706
 

Sökning: L773:2101 6275 OR L773:2100 014X OR L773:9782759819706 > A design study of V...

A design study of VOR: A versatile optimal resolution chopper spectrometer for the ESS

Deen, Pascale (författare)
Lund University,Lunds universitet,European Spallation Source ESS AB,Stiftelser och övriga anknutna verksamheter,Other Institutions and Utilities,European Spallat Source ESS AB, S-22100 Lund, Sweden
Vickery, A. (författare)
Univ Copenhagen, Niels Bohr Inst, DK-2100 Copenhagen, Denmark
Andersen, Ken (författare)
Lund University,Lunds universitet,European Spallation Source ESS AB,Stiftelser och övriga anknutna verksamheter,Other Institutions and Utilities,Univ Copenhagen, Niels Bohr Inst, DK-2100 Copenhagen, Denmark
visa fler...
Hall-Wilton, Richard (författare)
Mittuniversitetet,Lund University,Lunds universitet,European Spallation Source ESS AB,Stiftelser och övriga anknutna verksamheter,Other Institutions and Utilities,Avdelningen för elektronikkonstruktion,European Spallat Source ESS AB, S-22100 Lund, Sweden
visa färre...
 (creator_code:org_t)
2015-01-23
2015
Engelska.
Ingår i: QENS/WINS 2014 - 11th International Conference on Quasielastic Neutron Scattering and 6th International Workshopon Inelastic Neutron Spectrometers. - : EDP Sciences. - 2101-6275 .- 2100-014X. ; 83, s. 03002-03002
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • VOR, the versatile optimal resolution chopper spectrometer, is designed to probe dynamic phenomena that are currently inaccessible for inelastic neutron scattering due to flux limitations. VOR is a short instrument by the standards of the European Spallation Source (ESS), 30.2m moderator to sample, and provides instantaneous access to a broad dynamic range, 1-120 meV within each ESS period. The short instrument length combined with the long ESS pulse width enables a quadratic flux increase, even at longer wavelengths, by relaxing energy resolution from Delta E/E = 1% up to Delta E/E = 7%. This is impossible both on a long chopper spectrometer at the ESS and with instruments at short pulsed sources. In comparison to current day chopper spectrometers, VOR can offer an order of magnitude improvement in flux for equivalent energy resolutions, Delta E/E = 1-3%. Further relaxing the energy resolution enables VOR to gain an extra order of magnitude in flux. In addition, VOR has been optimised for repetition rate multiplication (RRM) and is therefore able to measure, in a single ESS period, 6-14 incident wavelengths, across a wavelength band of 9 angstrom with a novel chopper configuration that transmits all incident wavelengths with equivalent counting statistics. The characteristics of VOR make it a unique instrument with capabilities to access small, limited-lifetime samples and transient phenomena with inelastic neutron scattering.

Ämnesord

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Deen, Pascale
Vickery, A.
Andersen, Ken
Hall-Wilton, Ric ...
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Fysik
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Elektroteknik oc ...
Artiklar i publikationen
QENS/WINS 2014 - ...
Av lärosätet
Lunds universitet
Mittuniversitetet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy