SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Maki Hisataka)
 

Sökning: WFRF:(Maki Hisataka) > An elevated ratio o...

An elevated ratio of early to late diastolic filling velocity recovers after heart transplantation in a time-dependent manner

Irnamura, Teruhiko (författare)
University of Tokyo, Japan
Kinugawa, Koichiro (författare)
University of Tokyo, Japan
Shiga, Taro (författare)
University of Tokyo, Japan
visa fler...
Endo, Miyoko (författare)
University of Tokyo, Japan
Kato, Naoko (författare)
University of Tokyo, Japan
Inaba, Toshiro (författare)
University of Tokyo, Japan
Maki, Hisataka (författare)
University of Tokyo, Japan
Hatano, Masaru (författare)
University of Tokyo, Japan
Yao, Atsushi (författare)
University of Tokyo, Japan
Nishimura, Takashi (författare)
University of Tokyo, Japan
Hirata, Yasunobu (författare)
University of Tokyo, Japan
Kyo, Shunei (författare)
University of Tokyo, Japan
Ono, Minoru (författare)
University of Tokyo, Japan
Nagai, Ryozo (författare)
University of Tokyo, Japan
visa färre...
 (creator_code:org_t)
Elsevier, 2012
2012
Engelska.
Ingår i: Journal of Cardiology. - : Elsevier. - 0914-5087 .- 1876-4738. ; 60:4, s. 295-300
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BackgroundSeveral groups have reported that an elevated ratio of early (E) to late (A) diastolic filling velocities is observed in patients after heart transplantation. However, the mechanism has not been fully analyzed.MethodsSerial echocardiography and hemodynamic study were performed in 16 patients who had received heart transplantation and had no evidence of rejection during 1 month after the operation.ResultsOn Day 1 after the surgery, E/A ratio was higher and peak velocity of A wave was lower than normal range among the patients after heart transplantation. E/A ratio and peak velocity of A wave gradually normalized during 1 moth after the surgery. Meanwhile, early mitral annular velocity and pulmonary capillary wedge pressure remained within normal range during the study period.ConclusionsLonger ischemic time during heart transplantation procedure may cause atrial stunning, but it appears to recover within 1 month. We have to be alert to misinterpretation of this “psuedo-psuedonormal” mitral inflow pattern early after transplantation.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences (hsv//eng)

Nyckelord

Diastolic dysfunction; Echocardiography; Left atrium; Surgery

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy