SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Nair Gireesh)
 

Sökning: WFRF:(Nair Gireesh) > Heated atrium in mu...

Heated atrium in multi-story buildings : A design for better energy efficiency and social interactions

Danielski, Itai, 1973- (författare)
Mittuniversitetet,Avdelningen för ekoteknik och hållbart byggande,The Ekoteknik research group
Nair, Gireesh (författare)
Applied Physics and Electronics, Umeå university
Fröling, Morgan (författare)
Mittuniversitetet,Avdelningen för ekoteknik och hållbart byggande
 (creator_code:org_t)
2013
2013
Engelska.
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • The shape factor of a building expresses the ratio between the building’s thermal envelope area and its volume, or alternatively to its useful floor area. Buildings with lower shape factors will have lower heat losses through the thermal envelope and lower specific final energy demand. The shape factor of building could be reduced by a compact building shape design, and by increasing the volume of the building. However, the requirement for indoor natural light put a limit on the size of the building and therefore may limit the value of the shape factor. One possible solution to address this aspect is designing building with a heated atrium.An atrium is a large enclosed space within a building, and may have a glazed roof. In a multi-story apartment building an atrium has the potential to increase the social interaction between the residents and, with the right design, at the same time reduce the heating demand of the building due to lower building shape factor. However, the use of atrium in residential buildings in Nordic countries has not yet gained popularity.In this paper the impact of the heated atrium building with cylindrical shape design on the specific final energy is investigated by comparing such building design to conventional design buildings with similar floor area. The Nydalahuset project, in city Umeå in the north of Sweden, which is a multi-story residential building with a heated atrium, is used as a case study to investigate the affect of the atrium on the social interaction among the building occupants.The results show that heated atrium building with cylindrical shape design is a better energy efficient design than the conventional buildings. Such buildings in cold climate could help to reduce the heat losses through the thermal envelope and facilitate to achieve the passive house criteria. Moreover, the Nydalahuset project suggests that the atrium design could improve the social interaction of occupants in residential buildings.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Miljöanalys och bygginformationsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Environmental Analysis and Construction Information Technology (hsv//eng)

Nyckelord

Heated atrium
shape factor
social interaction
Nydalahuset
multi-story building
final energy demand
Social interaction

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy