SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Lundin Patrik)
 

Sökning: WFRF:(Lundin Patrik) > (2015-2019) > Membrane stress ana...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003394naa a2200373 4500
001oai:DiVA.org:hb-10183
003SwePub
008160625s2016 | |||||||||||000 ||eng|
024a https://urn.kb.se/resolve?urn=urn:nbn:se:hb:diva-101832 URI
024a https://doi.org/10.1016/j.bej.2016.06.0232 DOI
040 a (SwePub)hb
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Osadolor, Osagie Alex,d 1987-u Högskolan i Borås,Akademin för textil, teknik och ekonomi,Resource recovery4 aut0 (Swepub:hb)alos
2451 0a Membrane stress analysis of collapsible tanks andbioreactors
264 1b Elsevier BV,c 2016
338 a electronic2 rdacarrier
520 a Collapsible tanks, vessels or bioreactors are finding increasing usage in small/medium scaleprocesses because they offer flexibility and lower cost. However, if they are to be used atlarge scale, they need to be shown capable of handling the physical stress exerted on them.Because of their nonconventional shape and non-uniform pressure distribution, thin shellanalysis cannot be used in calculating their stress. Defining curvature in terms of pressureaddressed these challenges. Using curvature and numerical analysis, the membrane stress incollapsible tanks designed as bioreactors of volumes between 100-1000 m3 were calculated.When the liquid/gas height and static pressure are known, an equation for calculating tensionper length was developed. An equation that could calculate the liquid height from thebioreactor’s volume, dimensions and working capacity was generated. The equation gavevalues of liquid height with a maximum deviation of 3% from that calculated by curvatureanalysis. The stress values from the liquid height and tension equations had a maximumdeviation of 6% from those calculated by curvature analysis. The calculated tensile stress in a1000 m3 collapsible tank was 14.2 MPa. From these calculations, materials that optimize bothcost and safety can be selected when designing collapsible tanks.
650 7a TEKNIK OCH TEKNOLOGIERx Kemiteknikx Annan kemiteknik0 (SwePub)204992 hsv//swe
650 7a ENGINEERING AND TECHNOLOGYx Chemical Engineeringx Other Chemical Engineering0 (SwePub)204992 hsv//eng
653 a Pressure vessel; Collapsible tank; Bioreactor; Stress calculations; Stress relation; Curvature analysis; Biofuel production
653 a Resursåtervinning
653 a Resource Recovery
700a Lundin, Magnusu Högskolan i Borås,Akademin för textil, teknik och ekonomi,Resource recovery4 aut0 (Swepub:hb)MLU
700a Lennartsson, Patriku Högskolan i Borås,Akademin för textil, teknik och ekonomi,Resource recovery4 aut0 (Swepub:hb)PAT
700a Taherzadeh, Mohammadu Högskolan i Borås,Akademin för textil, teknik och ekonomi,Resource recovery4 aut0 (Swepub:hb)MJT
710a Högskolan i Boråsb Akademin för textil, teknik och ekonomi4 org
773t Biochemical engineering journald : Elsevier BVx 1369-703Xx 1873-295X
856u https://hb.diva-portal.org/smash/get/diva2:942559/FULLTEXT01.pdfx primaryx Raw objecty fulltext:postprint
856u http://hb.diva-portal.org/smash/get/diva2:942559/FULLTEXT01
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:hb:diva-10183
8564 8u https://doi.org/10.1016/j.bej.2016.06.023

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Osadolor, Osagie ...
Lundin, Magnus
Lennartsson, Pat ...
Taherzadeh, Moha ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Kemiteknik
och Annan kemiteknik
Artiklar i publikationen
Biochemical engi ...
Av lärosätet
Högskolan i Borås

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy