SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Yan Jinyue)
 

Sökning: WFRF:(Yan Jinyue) > Energy Flexibility ...

Energy Flexibility through the Integrated Energy Supply System in Buildings : A Case Study in Sweden

Zhang, Yang (författare)
KTH,Energiprocesser,KTH Royal Institute of Technology, Stockholm, Sweden
Campana, Pietro Elia (författare)
Mälardalens högskola,KTH,Energiprocesser,Mälardalen Univ, Sch Business Soc & Engn, SE-72123 Västerås, Sweden.,Framtidens energi
Yang, Ying (författare)
Mälardalens högskola,Framtidens energi
visa fler...
Lundblad, Anders Olof (författare)
RISE,Elektronik,RISE Res Inst Sweden, Div Safety & Transport Elect, SE-50462 Borås, Sweden.,Division Safety and Transport/Electronics, RISE Research Institutes of Sweden, SE-50462 Borås, Sweden
Yan, Jinyue (författare)
Mälardalens högskola,Framtidens energi
Yan, Jerry, 1959- (författare)
KTH,Energiprocesser,Mälardalen Univ, Sch Business Soc & Engn, SE-72123 Västerås, Sweden.
visa färre...
 (creator_code:org_t)
Elsevier BV, 2018
2018
Engelska.
Ingår i: Energy Procedia. - : Elsevier BV. - 1876-6102. ; , s. 564-569, s. 564-569
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • The increasing penetration level of renewable energies requires more flexibility measures at the consumption side. Flexible energy prices have been placed by energy providers to promote flexibility measures from energy users. However, because of the current energy supply system in buildings, these flexible energy prices haven't been fully taken advantage of. This study focuses on the integrated energy supply system in buildings. A Swedish office building is used as the case study. The integrated energy supply system is built by installing new components, including battery, heat pump and electrical heater, and hot water tank. Mixed Integer Linear Programming (MILP) problems are solved to determine the optimal component capacities and operation profiles. The results indicate that all the studied system configurations achieve lower net present cost (NPC) than the current system. It suggests that the integrated energy supply system can take advantage of the flexible energy prices and lower the overall energy cost in the building. Among the studied configurations, the combination of air source heat pump (ASHP) and electrical heater (EH) has the lowest investment cost. This combination also has the lowest NPC except in the scenario with low borehole cost. © 2018 The Authors. Published by Elsevier Ltd.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Energisystem (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Energy Systems (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Nyckelord

District Heating
Energy Flexibility
Heat Pump
MILP
Photovoltaic
Air source heat pumps
Costs
Electric appliances
Energy resources
Integer programming
Office buildings
Pumps
Water tanks
Energy supply system
Flexibility measures
Heat pumps
Mixed integer linear programming (MILP)
System configurations
Investments

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy