Sökning: L773:0065 2598 OR L773:2214 8019 >
Reduced oxygenation...
Reduced oxygenation in diabetic rat kidneys measured by T2* weighted magnetic resonance micro-imaging
-
- Edlund, Jenny (författare)
- Uppsala universitet,Institutionen för medicinsk cellbiologi
-
- Hansell, Peter (författare)
- Uppsala universitet,Integrativ Fysiologi
-
- Fasching, Angelica (författare)
- Uppsala universitet,Integrativ Fysiologi
-
visa fler...
-
- Liss, Per (författare)
- Uppsala universitet,Enheten för radiologi
-
- Weis, Jan (författare)
- Uppsala universitet,Enheten för radiologi
-
Glickson, Jerry D. (författare)
-
- Palm, Fredrik (författare)
- Uppsala universitet,Integrativ Fysiologi
-
visa färre...
-
(creator_code:org_t)
- Boston, MA : Springer US, 2009
- 2009
- Engelska.
-
Ingår i: Advances in Experimental Medicine and Biology. - Boston, MA : Springer US. - 0065-2598 .- 2214-8019. ; 645, s. 199-204
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- By applying invasive techniques for direct measurements of oxygen tension, we have reported decreased kidney oxygenation in experimental diabetes in rats. However, the non-invasive MRI technique utilizing the BOLD effect provides several advantages with the possibility to perform repetitive measurements in the same animals and in human subjects. In this study, we applied a modified single gradient echo micro-imaging sequence to detect the BOLD effect in kidneys of diabetic rats and compared the results to normoglycemic controls. All measurements were performed on inactin-anaesthetized adult male Wistar Furth rats. Diabetes was induced by streptozotocin (45 mg/kg) 14 days prior to MRI-analysis. Sixteen T2*-weighted image records (B0=1.5 T) were performed using radiofrequency spoiled gradient echo sequence with 2.6 ms step increments of TE (TE1=12 ms), while TR (75 ms) and bandwidth per pixel (71.4 Hz) were kept constant. T2* maps were computed by mono-exponential fitting of the pixel intensities. Relaxation rates R2* (1/T2*) in cortex and outer stripe of the outer medulla were similar in both groups (cortex for controls 22.3 +/- 0.4 vs. diabetics 23.1 +/- 1.8 Hz and outer stripe of outer medulla for controls 24.9 +/- 0.4 vs. diabetics 26.4 +/- 1.8 Hz; n=4 in both groups), whereas R2* was increased in the inner stripe of the outer medulla in diabetic rats (diabetics 26.1 +/- 2.4 vs. controls 18.8 +/- 1.4 Hz; n=4, P<0.05). This study demonstrates that experimental diabetes in rats induces decreased oxygenation of the renal outer medulla. Furthermore, the proposed T2*-weighted MR micro-imaging technique is suitable for detection of regional changes in kidney oxygenation in experimental animal models.
Nyckelord
- MEDICINE
- MEDICIN
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas