SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Jönsson Charlotta)
 

Sökning: WFRF:(Jönsson Charlotta) > Test-Retest Reliabi...

Test-Retest Reliability of Volume and Local Tissue Water Measurements in Lower Limbs of Healthy Women and Men

Jönsson, Charlotta (författare)
Lund University,Lunds universitet,Människan i rörelse: hälsa och rehabilitering,Forskargrupper vid Lunds universitet,Human Movement: health and rehabilitation,Lund University Research Groups,Skåne University Hospital
Bjurberg, Maria (författare)
Lund University,Lunds universitet,Huvud- och halscancergruppen,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Head and Neck Cancer Research Group,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Skåne University Hospital
Brogårdh, Christina (författare)
Lund University,Lunds universitet,Människan i rörelse: hälsa och rehabilitering,Forskargrupper vid Lunds universitet,Human Movement: health and rehabilitation,Lund University Research Groups
visa fler...
Johansson, Karin (författare)
Lund University,Lunds universitet,Människan i rörelse: hälsa och rehabilitering,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Human Movement: health and rehabilitation,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments
visa färre...
 (creator_code:org_t)
Mary Ann Liebert Inc, 2020
2020
Engelska 9 s.
Ingår i: Lymphatic Research and Biology. - : Mary Ann Liebert Inc. - 1539-6851 .- 1557-8585. ; 18:3, s. 261-269
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Measurements of lower limb (LL) volume and local tissue water by tissue dielectric constant (TDC) are common in lymphedema management. Knowledge of normal variability in health subjects is important and can serve as a base for early lymphedema diagnosis but is currently lacking. The aim of this study was to evaluate test-retest reliability of LL volume and TDC values in healthy women and men. Methods and Results: Thirty-three women and 28 men were measured twice, 2 weeks apart. Volume was calculated from circumferential measurements every 4 cm and TDC in 14 points. Test-retest reliability was evaluated using intraclass correlation coefficient (ICC), changes in the mean, standard error of measurement in percentage (SEM%), and smallest real difference in percentage (SRD%). For volume, reliability was high (ICC 0.99) and measurement errors were low in both women and men (SEM%: 1.1%-1.3%; SRD%: 3.1%-3.6%). For TDC, reliability was fair to excellent in women (ICC 0.63-0.93) and poor to excellent in men (ICC 0.21-0.89). Measurement errors were acceptable in all points in women (SEM%: 3.9%-10.2%; SRD% 10.8%-28.2%), but only in 11 points in men (SEM%: 3.9%-14.5%; SRD%: 10.9%-40.1%). The points close to bone and tendons in men had lower reliability and higher measurement errors. Conclusion: Measurements of LL volume and TDC are reliable in healthy women and men; both methods can be recommended. However, TDC points close to bone and tendons in men should be used with caution.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)

Nyckelord

anthropometry/instrumentation
healthy volunteers
lower extremity
reproducibility of results

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Jönsson, Charlot ...
Bjurberg, Maria
Brogårdh, Christ ...
Johansson, Karin
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinska och f ...
och Fysiologi
Artiklar i publikationen
Lymphatic Resear ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy