SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Nilson M)
 

Sökning: WFRF:(Nilson M) > MkII--a modified se...

MkII--a modified self-tapping Brånemark implant: 3-year results of a controlled prospective pilot study.

Olsson, M (författare)
Gothenburg University,Göteborgs universitet,Odontologiska institutionen,Institute of Odontology
Friberg, Bertil, 1950 (författare)
Gothenburg University,Göteborgs universitet,Odontologiska institutionen,Institute of Odontology
Nilson, H (författare)
Gothenburg University,Göteborgs universitet,Odontologiska institutionen,Institute of Odontology
visa fler...
Kultje, C (författare)
Gothenburg University,Göteborgs universitet,Odontologiska institutionen,Institute of Odontology
visa färre...
 (creator_code:org_t)
1995
1995
Engelska.
Ingår i: The International journal of oral & maxillofacial implants. - 0882-2786. ; 10:1, s. 15-21
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A modified self-tapping implant (MkII) with improved cutting characteristics has been designed for use in both maxillae and mandibles. Four sequential studies were conducted to evaluate the outcome of the MkII implant compared to the standard implant. The results presented here are from the extended pilot study that has been conducted as an intra-individual study of 103 patients; ie, each patient received both test (MkII) and control (standard Brånemark System) implants. Seventy patients were treated in the mandible and 33 in the maxilla. The cumulative survival rates and marginal bone resorption showed equivalent results for both test and control implants. Three-year cumulative survival rates were 87.9% and 86.8% for test and control implants in maxilla, respectively, and 99.5% and 100% in mandibles, respectively. The mean marginal bone resorption was approximately 0.5 (control) to (MK II) 0.6 mm after 3 years of function. A total of 288 test implants and 275 control implants were placed. All implants, both test and control, could be placed in an appropriate implant position, but 21.2% of the implants were not fully seated by machine power only; the use of a manual cylinder wrench for the final turns was necessary. During the last phase of the study, however, with an increase in twist-drill diameter from 3.0 to 3.15 mm and an increased motor torque, the prerequisites of successful implant placement into final position were met.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

Adult
Aged
Aged
80 and over
Alveolar Bone Loss
etiology
Dental Implants
adverse effects
Dental Prosthesis Design
Female
Humans
Male
Middle Aged
Pilot Projects
Prospective Studies
Prosthesis Failure
Treatment Outcome

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Olsson, M
Friberg, Bertil, ...
Nilson, H
Kultje, C
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Artiklar i publikationen
The Internationa ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy