Sökning: L773:0026 2862 > Reproducibility of ...

Reproducibility of Laser Doppler Flowmetry in gingival microcirculation. A study on six different protocols

Ajan, Aida (författare)
Linköpings universitet,Avdelningen för kirurgi, ortopedi och onkologi,Medicinska fakulteten,Region Östergötland, Käkkliniken US
Roberg, Karin (författare)
Linköpings universitet,Avdelningen för cellbiologi,Medicinska fakulteten,Region Östergötland, Öron- näsa- och halskliniken
Fredriksson, Ingemar (författare)
Linköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten
visa fler...
Abtahi, Jahan (författare)
Linköpings universitet,Avdelningen för kirurgi, ortopedi och onkologi,Medicinska fakulteten,Region Östergötland, Käkkliniken US
visa färre...
 (creator_code:org_t)
ACADEMIC PRESS INC ELSEVIER SCIENCE, 2024
2024
Engelska.
Ingår i: Microvascular Research. - : ACADEMIC PRESS INC ELSEVIER SCIENCE. - 0026-2862 .- 1095-9319. ; 153
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objectives: Laser Doppler Flowmetry (LDF) is a non-invasive technique for the assessment of tissue blood flow, but increased reproducibility would facilitate longitudinal studies. The aim of the study was to assess the interday reproducibility of Laser Doppler Flowmetry (LDF) at rest, at elevated local temperatures, and with the use of the vasodilator Methyl Nicotinate (MN) in six interconnected protocols for the measurement of the blood supply to the microvascular bed of the gingiva. Methods: Ten healthy volunteers were included. Interweek LDF measurements with custom-made acrylic splints were performed. Six protocols were applied in separate regions of interest (ROI): 1; basal LDF, 2; LDF with thermoprobe 42 degrees C, 3; LDF with thermoprobe 45 degrees C, 4; LDF with thermoprobe 42 degrees C and MN, 5; LDF with thermoprobe 45 C and MN and 6; LDF with MN. Results: Intra-individual reproducibility was assessed by the within -subject coefficient of variation (wCV) and the intraclass correlation coefficient (ICC). Basal LDF measurements demonstrated high reproducibility with wCV 11.1 in 2 min and 10.3 in 5 min. ICC was 0.9 and 0.92. wCV after heat and MN was 4.9-10.3 and ICC 0.82-0.93. The topically applied MN yielded increased blood flow. Conclusion: This is the first study evaluating the reproducibility of basal LDF compared to single or multiple vasodilatory stimuli in gingiva. Multiple collector fibers probe and stabilizing acrylic splints are recommended. Vasodilatory stimulation showed a tendency toward higher reproducibility. Furthermore, MN yields vasodilation in gingiva.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

Laser Doppler Flowmetry; Microcirculation; Local heating; Thermoprobe; Methyl Nicotinate

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ajan, Aida
Roberg, Karin
Fredriksson, Ing ...
Abtahi, Jahan
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk labora ...
Artiklar i publikationen
Microvascular Re ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy