SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Kartus Jüri 1955)
 

Sökning: WFRF:(Kartus Jüri 1955) > Long-term clinical ...

Long-term clinical and ultrasound evaluation after arthroscopic acromioplasty in patients with partial rotator cuff tears

Kartus, Jüri, 1955 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Kartus, C. (författare)
Rostgard-Christensen, L. (författare)
visa fler...
Sernert, Ninni, 1954 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Read, J. (författare)
Perko, M. (författare)
visa färre...
 (creator_code:org_t)
2006
2006
Engelska.
Ingår i: Arthroscopy. - 1526-3231. ; 22:1, s. 44-9
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: Clinical and ultrasound evaluation of patients who had undergone debridement of a partial rotator cuff tear in conjunction with an arthroscopic acromioplasty. TYPE OF STUDY: Retrospective follow-up study. METHODS: Thirty-three consecutive patients were included in the study; 26 of the 33 (79%) patients underwent ultrasound evaluation of both shoulders and were examined by independent observers after a follow-up period of 101 months (range, 60 to 128 months; minimum, 5 years). RESULTS: The median time between onset of symptoms and surgery was 24 months (range, 6 to 360 months). At follow-up, the Constant score was 65 points (range, 15-98). The Constant score on the contralateral side was 84 points (range, 15-96; P < .0001). The strength in abduction was 4.7 kg (range, 1.2 to 11.1 kg) on the operated side and 5.1 kg (range, 1.8 to 10.4 kg) on the contralateral side (not significant). Twelve of the 26 patients reported discomfort or pain in the contralateral shoulder and during the follow-up period, and 3 of 26 had undergone an arthroscopic acromioplasty of the contralateral shoulder. Two of 26 patients underwent further surgery of the index shoulder during the follow-up period. The visual analogue score for pain for the index shoulder was 20 mm (range, 0 to 85). The ultrasound evaluation revealed that 9 of 26 patients had a full-thickness rotator cuff tear in the index shoulder and, of these, 3 of 9 were bilateral. CONCLUSIONS: It appears that an arthroscopic acromioplasty and rotator cuff debridement in patients with partial tears does not protect the rotator cuff from undergoing further degeneration. LEVEL OF EVIDENCE: Level IV.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

Acromion/*surgery
Arthroscopy/*methods
Follow-Up Studies
Humans
Reproducibility of Results
Rotator Cuff/*injuries/*surgery/ultrasonography
Shoulder Joint/*injuries/surgery/ultrasonography
Time Factors
Treatment Outcome

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Kartus, Jüri, 19 ...
Kartus, C.
Rostgard-Christe ...
Sernert, Ninni, ...
Read, J.
Perko, M.
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kirurgi
Artiklar i publikationen
Arthroscopy
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy