SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Klementiev K.)
 

Sökning: WFRF:(Klementiev K.) > The BALDER Beamline...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00004411naa a2200433 4500
001oai:lup.lub.lu.se:5733b48e-239a-42d4-9ae9-93ae306ae793
003SwePub
008170222s2016 | |||||||||||000 ||eng|
009oai:slubar.slu.se:94342
024a https://lup.lub.lu.se/record/5733b48e-239a-42d4-9ae9-93ae306ae7932 URI
024a https://doi.org/10.1088/1742-6596/712/1/0120232 DOI
024a https://res.slu.se/id/publ/943422 URI
040 a (SwePub)lud (SwePub)slu
041 a engb eng
042 9 SwePub
072 7a art2 swepub-publicationtype
072 7a ref2 swepub-contenttype
100a Klementiev, K.u Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory4 aut0 (Swepub:lu)biok-ksi
2451 0a The BALDER Beamline at the MAX IV Laboratory
264 c 2016-06-01
264 1b IOP Publishing,c 2016
520 a X-ray absorption spectroscopy (XAS) includes well-established methods to study the local structure around the absorbing element - extended X-ray absorption fine structure (EXAFS), and the effective oxidation number or to quantitatively determine the speciation of an element in a complex matrix - X-ray absorption near-edge structure (XANES). The increased brilliance and intensities available at the new generation of synchrotron light sources makes it possible to study, in-situ and in-operando, much more dilute systems with relevance for natural systems, as well as the micro-scale variability and dynamics of chemical reactions on the millisecond time-scale. The design of the BALDER beamline at the MAX IV Laboratory 3 GeV ring has focused on a high flux of photons in a wide energy range, 2.4-40 keV, where the K-edge is covered for the elements S to La, and the L 3-edge for all elements heavier than Sb. The overall design of the beamline will allow large flexibility in energy range, beam size and data collection time. The other focus of the beamline design is the possibility to perform multi-technique analyses on samples. Development of sample environment requires focus on implementation of auxiliary methods in such a way that techniques like Fourier transform infrared (FTIR) spectroscopy, UV-Raman spectroscopy, X-ray diffraction and/or mass spectrometry can be performed simultaneously as the XAS study. It will be a flexible system where different instruments can be plugged in and out depending on the needs for the particular investigation. Many research areas will benefit from the properties of the wiggler based light source and the capabilities to perform in-situ and in-operando measurements, for example environmental and geochemical sciences, nuclear chemistry, catalysis, materials sciences, and cultural heritage.
650 7a NATURVETENSKAPx Fysikx Acceleratorfysik och instrumentering0 (SwePub)103062 hsv//swe
650 7a NATURAL SCIENCESx Physical Sciencesx Accelerator Physics and Instrumentation0 (SwePub)103062 hsv//eng
650 7a TEKNIK OCH TEKNOLOGIERx Materialteknikx Annan materialteknik0 (SwePub)205992 hsv//swe
650 7a ENGINEERING AND TECHNOLOGYx Materials Engineeringx Other Materials Engineering0 (SwePub)205992 hsv//eng
700a Norén, K.u Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory4 aut0 (Swepub:lu)maxl-kin
700a Carlson, S.u Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory4 aut0 (Swepub:lu)inor-sca
700a Sigfridsson Clauss, K. G Vu Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory4 aut0 (Swepub:lu)biok-ksi
700a Persson, Ingmaru Sveriges lantbruksuniversitet,Swedish University of Agricultural Sciences,Institutionen för Kemi och Bioteknologi,The Department of Chemistry and Biotechnology4 aut0 (Swepub:slu)49008
710a Lunds universitetb MAX IV-laboratoriet4 org
710a Sveriges lantbruksuniversitet
773t Journal of Physics: Conference Seriesd : IOP Publishingg 712:1q 712:1x 1742-6588x 1742-6596
856u http://dx.doi.org/10.1088/1742-6596/712/1/012023x freey FULLTEXT
856u https://doi.org/10.1088/1742-6596/712/1/012023
856u https://pub.epsilon.slu.se/id/eprint/15604/contentsx primaryx Raw objectx freey FULLTEXT
8564 8u https://lup.lub.lu.se/record/5733b48e-239a-42d4-9ae9-93ae306ae793
8564 8u https://doi.org/10.1088/1742-6596/712/1/012023
8564 8u https://res.slu.se/id/publ/94342

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy