SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Lind Carl Mikael)
 

Sökning: WFRF:(Lind Carl Mikael) > Mind the gap – deve...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00004117naa a2200505 4500
001oai:research.chalmers.se:4302c1db-0bb1-4d6d-a9e1-3af55b310281
003SwePub
008220814s2022 | |||||||||||000 ||eng|
009oai:DiVA.org:kth-317349
009oai:prod.swepub.kib.ki.se:150563589
024a https://research.chalmers.se/publication/5315842 URI
024a https://doi.org/10.1016/j.apergo.2022.1038412 DOI
024a https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-3173492 URI
024a http://kipublications.ki.se/Default.aspx?queryparsed=id:1505635892 URI
040 a (SwePub)cthd (SwePub)kthd (SwePub)ki
041 a engb eng
042 9 SwePub
072 7a art2 swepub-publicationtype
072 7a ref2 swepub-contenttype
100a Forsman, Mikael,c Professoru KTH,Ergonomi,IMM Institute of Environmental Medicine, Karolinska Institutet, Stockholm, SE-171 77, Sweden; Centre for Occupational and Environmental Medicine, Stockholm County Council, Stockholm, SE-113 65, Sweden,Stockholms läns landsting,Stockholm County Council,Karolinska Institutet,Kungliga Tekniska Högskolan (KTH),Royal Institute of Technology (KTH)4 aut0 (Swepub:kth)u1iq0ct2
2451 0a Mind the gap – development of conversion models between accelerometer- and IMU-based measurements of arm and trunk postures and movements in warehouse work
264 1b Elsevier BV,c 2022
338 a electronic2 rdacarrier
500 a QC 20220909
520 a Sensor type (accelerometers only versus inertial measurement units, IMUs) and angular velocity computational method (inclination versus generalized velocity) have been shown to affect the measurements of arm and trunk movements. This study developed models for conversions between accelerometer and IMU measurements of arm and trunk inclination and between accelerometer and IMU measurements of inclination and generalized (arm) velocities. Full-workday recordings from accelerometers and IMUs of arm and trunk postures and movements from 38 warehouse workers were used to develop 4 angular (posture) and 24 angular velocity (movement) conversion models for the distributions of the data. A power function with one coefficient and one exponent was used, and it correlated well (r2 > 0.999) in all cases to the average curves comparing one measurement with another. These conversion models facilitate the comparison and merging of measurements of arm and trunk movements collected using the two sensor types and the two computational methods.
650 7a TEKNIK OCH TEKNOLOGIERx Medicinteknikx Medicinsk laboratorie- och mätteknik0 (SwePub)206012 hsv//swe
650 7a ENGINEERING AND TECHNOLOGYx Medical Engineeringx Medical Laboratory and Measurements Technologies0 (SwePub)206012 hsv//eng
650 7a TEKNIK OCH TEKNOLOGIERx Medicinteknikx Annan medicinteknik0 (SwePub)206992 hsv//swe
650 7a ENGINEERING AND TECHNOLOGYx Medical Engineeringx Other Medical Engineering0 (SwePub)206992 hsv//eng
650 7a TEKNIK OCH TEKNOLOGIERx Naturresursteknikx Havs- och vattendragsteknik0 (SwePub)207062 hsv//swe
650 7a ENGINEERING AND TECHNOLOGYx Environmental Engineeringx Ocean and River Engineering0 (SwePub)207062 hsv//eng
653 a Sensor conversion
653 a Field measurement
653 a Inertial measurement unit
700a Fan, Xuelongu Karolinska Institutet4 aut
700a Rhen, Ida-Märta,d 1975u Karolinska Institutet4 aut0 (Swepub:cth)idamarta
700a Lind, Carl Mikaelu Karolinska Institutet4 aut
710a KTHb Ergonomi4 org
773t Applied Ergonomicsd : Elsevier BVg 105q 105x 0003-6870x 1872-9126
856u https://research.chalmers.se/publication/531584/file/531584_Fulltext.pdfx primaryx freey FULLTEXT
856u https://doi.org/10.1016/j.apergo.2022.103841y Fulltext
8564 8u https://research.chalmers.se/publication/531584
8564 8u https://doi.org/10.1016/j.apergo.2022.103841
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-317349
8564 8u http://kipublications.ki.se/Default.aspx?queryparsed=id:150563589

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy