SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Paderni Carlo)
 

Sökning: WFRF:(Paderni Carlo) > Efficacy and safety...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00004480naa a2200757 4500
001oai:DiVA.org:mau-6496
003SwePub
008200228s2011 | |||||||||||000 ||eng|
024a https://urn.kb.se/resolve?urn=urn:nbn:se:mau:diva-64962 URI
024a https://doi.org/10.1002/art.277662 DOI
040 a (SwePub)mau
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Strietzel, Frank P4 aut
2451 0a Efficacy and safety of an intraoral electrostimulation device for xerostomia relief :b A multicenter randomized trial
264 c 2010-12-28
264 1b Wiley,c 2011
338 a print2 rdacarrier
520 a Objective: The objective of the study was to evaluate the efficacy in treating xerostomia and the safety of an intraoral electrostimulation device, containing stimulating electrodes, an electronic circuit and a power source. The device delivers electrostimulation through the oral mucosa to the lingual nerve, in order to enhance the salivary reflex. Methods: The device was tested on a sample of patients with xerostomia due to Sjögren’s syndrome and other sicca conditions in a prospective randomized multi-center trial consisting of two stages: (I) a double blind, cross-over designed stage to compare the effects of the electrically “active” device with the “sham” device, both used for one month, and (II) a 3- month open label stage to assess the long-term influence of the “active” device. Improvement of xerostomia severity from baseline was the primary outcome. Results: A total of 114 subjects were randomized. In Stage I, “active” device performed better than “sham” for patient-reported xerostomia severity (p<0.002), xerostomia frequency (p<0.05), quality of life impairment (p<0.01) and swallowing difficulty (p<0.02). At the end of Stage II, statistically significant improvements were verified for patient-reported xerostomia severity (p<0.0001), xerostomia frequency (p<0.0001), oral discomfort (p<0.001), speech difficulty (p<0.02) and sleeping difficulty (p<0.001), and for resting salivary flow-rate (p<0.01). Conclusion: Daily use of the device alleviated oral dryness, discomfort and some complications of xerostomia, such as speech and sleeping difficulties, and increased salivary output. The results show a cumulative positive effect of the device over the period of the study, from baseline to the trial’s end.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Odontologi0 (SwePub)302162 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Dentistry0 (SwePub)302162 hsv//eng
653 a xerostomia
653 a dry mouth
653 a salivary gland hypofunction
653 a saliva
653 a electrical stimulation
653 a electrostimulation
653 a Sjögren’s syndrome
700a Lafaurie, Gloria I4 aut
700a Bautista Mendoza, Gloria R4 aut
700a Alajbeg, Ivan4 aut
700a Pejda, Slavica4 aut
700a Vuleti?, Lea4 aut
700a Mantilla, Rubén4 aut
700a Falcão, Denise P4 aut
700a Leal, Soraya C4 aut
700a Barreto Bezerra, Ana C4 aut
700a Tran, Simon D4 aut
700a Ménard, Henri A4 aut
700a Kimoto, Suguru4 aut
700a Pan, Shaoxia4 aut
700a Martín-Granizo, Rafael A4 aut
700a Maniegas Lozano, M Lourdes4 aut
700a Zunt, Susan L4 aut
700a Krushinski, Cheryl A4 aut
700a Melilli, Dario4 aut
700a Campisi, Giuseppina4 aut
700a Paderni, Carlo4 aut
700a Dolce, Sonia4 aut
700a Yepes, Juan F4 aut
700a Lindh, Liselottu Malmö högskola,Odontologiska fakulteten (OD)4 aut0 (Swepub:mau)odlili
700a Koray, Meltem4 aut
700a Mumcu, Gonca4 aut
700a Elad, Sharon4 aut
700a Zeevi, Itai4 aut
700a Aldape Barrios, Beatriz C4 aut
700a López Sánchez, Rodrigo M4 aut
700a Beiski, Ben Z4 aut
700a Wolff, Andy4 aut
700a Konttinen, Yrjö T4 aut
710a Malmö högskolab Odontologiska fakulteten (OD)4 org
773t Arthritis and Rheumatismd : Wileyg 63:1, s. 180-190q 63:1<180-190x 0004-3591x 1529-0131
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:mau:diva-6496
8564 8u https://doi.org/10.1002/art.27766

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy