SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sigfridsson Clauss Kajsa)
 

Sökning: WFRF:(Sigfridsson Clauss Kajsa) > Anaerobic fixed-tar...

Anaerobic fixed-target serial crystallography using sandwiched silicon nitride membranes

Bjelčić, Monika (författare)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
Sigfridsson Clauss, Kajsa G.V. (författare)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
Aurelius, Oskar (författare)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
visa fler...
Milas, Mirko (författare)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
Nan, Jie (författare)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
Ursby, Thomas (författare)
Lund University,Lunds universitet,MAX IV-laboratoriet,LINXS - Institute of advanced Neutron and X-ray Science,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,MAX IV Laboratory,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2023
2023
Engelska 8 s.
Ingår i: Acta Crystallographica Section D: Structural Biology. - 2059-7983. ; 79:Pt 11, s. 1018-1025
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In recent years, the emergence of serial crystallography, initially pioneered at X-ray free-electron lasers (XFELs), has sparked a growing interest in collecting macromolecular crystallographic data at room temperature. Various fixed-target serial crystallography techniques have been developed, ranging from commercially available chips to in-house designs implemented at different synchrotron facilities. Nevertheless, there is currently no commercially available chip (known to the authors) specifically designed for the direct handling of oxygen-sensitive samples. This study presents a methodology employing silicon nitride chips arranged in a 'sandwich' configuration, enabling reliable room-temperature data collection from oxygen-sensitive samples. The method involves the utilization of a custom-made 3D-printed assembling tool and a MX sample holder. To validate the effectiveness of the proposed method, deoxyhemoglobin and methemoglobin samples were investigated using the BioMAX X-ray macromolecular crystallography beamline, the Balder X-ray absorption spectroscopy beamline and UV-Vis absorption spectroscopy.

Ämnesord

NATURVETENSKAP  -- Biologi -- Strukturbiologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences -- Structural Biology (hsv//eng)

Nyckelord

anaerobic data collection
fixed-target serial crystallography
hemoglobin
sample supports
sandwiched silicon nitride membranes

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy