SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Telg G.)
 

Sökning: WFRF:(Telg G.) > (2015-2019) > Budesonide inhaler ...

Budesonide inhaler device switch patterns in an asthma population in Swedish clinical practice (ASSURE)

Ekberg-Jansson, Ann, 1960 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för medicin, avdelningen för invärtesmedicin och klinisk nutrition,Institute of Medicine, Department of Internal Medicine and Clinical Nutrition
Svenningsson, I. (författare)
Stratelis, G. (författare)
visa fler...
Telg, G. (författare)
Thuresson, M. (författare)
Nilsson, F. (författare)
visa färre...
 (creator_code:org_t)
2015-08-03
2015
Engelska.
Ingår i: International journal of clinical practice. - : Blackwell Publishing Ltd. - 1368-5031. ; 69:10, s. 1171-1178
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background Dry powder inhaler (DPI) device switch in asthma treatment could potentially increase with the entrance of new devices. We examined the switch patterns of budesonide (BUD) DPI analogues available in Sweden. Methods This observational real-life study linked primary healthcare medical records data from the Västra Götaland region to national Swedish registries, and included asthma patients (ICD-10-CM J45) prescribed BUD in a multidose DPI. Index date: first dispense of BUD DPI. Switch date: prescription of another BUD DPI device. Study outcomes (switch vs. non-switch) were exacerbations and prescription of short-acting β2-agonists. Study period was 1 July 2005 to 31 October 2013. Results Overall, 15,169 asthma patients were on treatment with BUD DPI; 1178 (7.35%) switched to another BUD DPI during the study. Pair-wise 1:1 matching of switchers vs. non-switchers resulted in two groups of 463 patients each (mean age 36 years, 55% female patients). A 25% higher exacerbation rate was seen postswitch (0.40 vs. 0.32; p = 0.047). Switchers were 4.5 year younger and had lower medication possession rate than non-switchers. Switch without primary healthcare visit did not differ between groups regarding consultations and exacerbations (no visit 4.96 and 0.90; visit 4.29 and 0.77, respectively). However, patients without primary healthcare visit at switch had significantly more outpatient hospital visits (2.01 vs. 0.81; p < 0.001). Conclusions Considering the low switch rate, asthma patients and physicians in Swedish general practice seem reluctant to switch to another BUD DPI device. Switch, especially without primary healthcare visit, was associated with decreased asthma control resulting in higher exacerbation rate and more outpatient hospital visits. © 2015 John Wiley & Sons Ltd.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Lungmedicin och allergi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Respiratory Medicine and Allergy (hsv//eng)

Nyckelord

budesonide
adult
asthma
clinical effectiveness
cohort analysis
controlled study
disease exacerbation
disease registry
dry powder inhaler
female
human
major clinical study
male
metered dose inhaler
observational study
outcome assessment
prescription

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy