Sökning: WFRF:(Henriksson Mikael)
> (2015-2019) >
Changes in f-wave c...
Changes in f-wave characteristics during cryoballoon catheter ablation
-
- Henriksson, Mikael (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
- García-Alberola, Arcadi (författare)
- University of Murcia
-
- Goya, Rebeca (författare)
- Rey Juan Carlos University
-
visa fler...
-
- Vadillo, Alba (författare)
- Rey Juan Carlos University
-
- Melgarejo-Meseguer, Francisco Manuel (författare)
- University of Murcia
-
- Sandberg, Frida (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
- Sörnmo, Leif (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
visa färre...
-
(creator_code:org_t)
- 2018-10-04
- 2018
- Engelska 1 s.
-
Ingår i: Physiological Measurement. - : IOP Publishing. - 0967-3334 .- 1361-6579. ; 39:10
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- OBJECTIVE: Changes in ECG-derived parameters are studied in atrial fibrillation (AF) patients undergoing cryoballoon catheter ablation.APPROACH: Parameters characterizing f-wave frequency, morphology by phase dispersion, and amplitude are estimated using a model-based statistical approach. These parameters are studied before, during, and after ablation, as well as for AF type (paroxysmal/persistent). Seventy-seven (49/28 paroxysmal/persistent) AF patients undergoing de novo catheter ablation are included in the study, out of which 31 (16/15 paroxysmal/persistent) were in AF during the whole procedure. A signal quality index (SQI) is used to identify analyzable segments.MAIN RESULTS: f-wave frequency decreased significantly during ablation (p = 0.001), in particular after ablation of the inferior right pulmonary vein (p < 0.05). Frequency and phase dispersion differed significantly between paroxysmal and persistent AF (p = 0.001 and p < 0.05, respectively).SIGNIFICANCE: This study demonstrates that a decrease in f-wave frequency can be distinguished during catheter ablation. The use of an SQI ensures reliable analysis and produces results significantly different from those obtained without an SQI.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas