SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Ekberg Lars)
 

Sökning: WFRF:(Ekberg Lars) > Characterization of...

Characterization of indoor sources of fine and ultrafine particles: a study conducted in a full scale chamber

Afshari, A (författare)
Matson, Uve, 1977 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Ekberg, Lars, 1962 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
 (creator_code:org_t)
Hindawi Limited, 2005
2005
Engelska.
Ingår i: Indoor Air. - : Hindawi Limited. - 1600-0668 .- 0905-6947. ; 15:2, s. 141-150
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Humans and their activities are known to generate considerable amounts of particulate matter indoors. Some of the activities are cooking, smoking and cleaning. In this study 13 different particle sources were for the first time examined in a 32 m3 full-scale chamber with an air change rate of 1.7 ± 0.1/h. Two different instruments, a condensation particle counter (CPC) and an optical particle counter (OPC) were used to quantitatively determine ultrafine and fine particle emissions, respectively. The CPC measures particles from 0.02 μm to larger than 1.0 μm. The OPC was adjusted to measure particle concentrations in eight fractions between 0.3 and 1.0 μm. The sources were cigarette side-stream smoke, pure wax candles, scented candles, a vacuum cleaner, an air-freshener spray, a flat iron (with and without steam) on a cotton sheet, electric radiators, an electric stove, a gas stove, and frying meat. The cigarette burning, frying meat, air freshener spray and gas stove showed a particle size distribution that changed over time towards larger particles. In most of the experiments the maximum concentration was reached within a few minutes. Typically, the increase of the particle concentration immediately after activation of the source was more rapid than the decay of the concentration observed after deactivation of the source. The highest observed concentration of ultrafine particles was approximately 241,000 particles/cm 3 and originated from the combustion of pure wax candles. The weakest generation of ultrafine particles (1.17 × 107 particles per second) was observed when ironing without steam on a cotton sheet, which resulted in a concentration of 550 particles/cm3 in the chamber air. The highest generation rate (1.47 × 1010 particles per second) was observed in the radiator test.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Nyckelord

ultrafine particles

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Afshari, A
Matson, Uve, 197 ...
Ekberg, Lars, 19 ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Samhällsbyggnads ...
och Husbyggnad
Artiklar i publikationen
Indoor Air
Av lärosätet
Chalmers tekniska högskola

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy