Sökning: WFRF:(Petersson Christer) > Metallized and oxid...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 05458naa a2200793 4500 | |
001 | oai:DiVA.org:kth-4959 | |
003 | SwePub | |
008 | 050303s2004 | |||||||||||000 ||eng| | |
009 | oai:DiVA.org:miun-2166 | |
009 | oai:DiVA.org:kth-47387 | |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-49592 URI |
024 | 7 | a https://doi.org/10.1109/TNS.2004.8295792 DOI |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:miun:diva-21662 URI |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-473872 URI |
040 | a (SwePub)kthd (SwePub)miun | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a art2 swepub-publicationtype |
100 | 1 | a Badel, Xavieru KTH,Mikroelektronik och informationsteknik, IMIT4 aut0 (Swepub:kth)u1ds8vw2 |
245 | 1 0 | a Metallized and oxidized silicon macropore arrays filled with a scintillator for CCD-based X-ray imaging detectors |
264 | 1 | b IEEE,c 2004 |
338 | a print2 rdacarrier | |
500 | a QC 20100831. Konferens: Nuclear Science Symposium/Medical Imaging Conference/13th International Workshop on Room-Temperature Semiconductor X-and Gamma-Ray Dectectors/Symposium on Nuclear Power Systems, Portland, OR, OCT 19-25, 2003. | |
500 | a Nuclear Science Symposium/Medical Imaging Conference/13th International Workshop on Room-Temperature Semiconductor X-and Gamma-Ray Dectectors/Symposium on Nuclear Power Systems, oct 19-25, 2003, Portland, OR | |
500 | a QC 20111109 | |
520 | a Silicon charge-coupled devices (CCDs) covered with a scintillating film are now available on the market for use in digital medical imaging. However, these devices could still be improved in terms of sensitivity and especially spatial resolution by coating the CCD with an array of scintillating waveguides. In this paper, such waveguides were fabricated by first etching pores in silicon, then performing metallization or oxidation of the pore walls and finally filling the pores with CsI(TI). The resulting structures were observed using scanning electron microscopy and tested under X-ray exposure. Theoretical efficiencies of macropore arrays filled with CsI(TI) were also calculated, indicating that the optimal pore depth for metallized macropore arrays is about 80 mum while it is around 350 mum for oxidized ones. This result, together with the roughness of the metal coating, explains why lower SNR values were measured with the metallized macropores. Indeed, the macropore arrays had depths in the range of 210-390 mum, which is favorable to oxidized structures. | |
650 | 7 | a TEKNIK OCH TEKNOLOGIERx Elektroteknik och elektronikx Annan elektroteknik och elektronik0 (SwePub)202992 hsv//swe |
650 | 7 | a ENGINEERING AND TECHNOLOGYx Electrical Engineering, Electronic Engineering, Information Engineeringx Other Electrical Engineering, Electronic Engineering, Information Engineering0 (SwePub)202992 hsv//eng |
650 | 7 | a TEKNIK OCH TEKNOLOGIERx Elektroteknik och elektronik0 (SwePub)2022 hsv//swe |
650 | 7 | a ENGINEERING AND TECHNOLOGYx Electrical Engineering, Electronic Engineering, Information Engineering0 (SwePub)2022 hsv//eng |
653 | a CsI(TI) | |
653 | a Pixellated detectors | |
653 | a Scintillating wave-guides | |
653 | a X-ray imaging | |
653 | a Cesium compounds | |
653 | a Imaging techniques | |
653 | a Metallizing | |
653 | a Optical resolving power | |
653 | a Optical waveguides | |
653 | a Phosphors | |
653 | a Scanning electron microscopy | |
653 | a Signal to noise ratio | |
653 | a Silicon | |
653 | a X rays | |
653 | a CsI(Tl) | |
653 | a Pixellated detectors | |
653 | a Scintillating waveguides | |
653 | a X-ray imaging | |
653 | a Charge coupled devices | |
653 | a Electrophysics | |
653 | a Elektrofysik | |
653 | a Electrical engineering, electronics and photonics | |
700 | 1 | a Linnros, Janu KTH,Mikroelektronik och informationsteknik, IMIT4 aut0 (Swepub:kth)u1t79mee |
700 | 1 | a Kleimann, P.u LENAC, Univ.́ Claude Bernard Lyon-I, Villeurbanne4 aut |
700 | 1 | a Norlin, Börjeu Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013)4 aut0 (Swepub:miun)bornor |
700 | 1 | a Koskiahde, E.u Metorex International Oy, Espoo4 aut |
700 | 1 | a Valpas, K.u Metorex International Oy, Espoo4 aut |
700 | 1 | a Nenonen, S.u Metorex International Oy, Espoo4 aut |
700 | 1 | a Petersson, Stureu KTH,Mikroelektronik och informationsteknik, IMIT,Department of Microelectronics, Roy. Inst. of Technology of Sweden, Kista4 aut0 (Swepub:miun)stupet |
700 | 1 | a Fröjdh, Christeru Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013)4 aut0 (Swepub:miun)chrfro |
710 | 2 | a KTHb Mikroelektronik och informationsteknik, IMIT4 org |
773 | 0 | t IEEE Transactions on Nuclear Scienced : IEEEg 51:3, s. 1001-1005, s. 1006-1010q 51:3<1001-1005x 0018-9499x 1558-1578 |
773 | 0 | t 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5d : IEEEg 51:3, s. 1001-1005, s. 1006-1010q 51:3<1001-1005<1006-1010 |
856 | 4 | u http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=1351864y IEEE Xplore |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-4959 |
856 | 4 8 | u https://doi.org/10.1109/TNS.2004.829579 |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:miun:diva-2166 |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-47387 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy