Sökning: L773:1718 4304 >
High versus low ult...
High versus low ultrafiltration rates during experimental peritoneal dialysis in rats : Acute effects on plasma volume and systemic haemodynamics
-
- Helman, Jakob (författare)
- Lund University,Lunds universitet,Njurmedicin,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Nephrology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
-
- M Öberg, Carl (författare)
- Lund University,Lunds universitet,Njurmedicin,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Njurfysiologi och peritonealdialys,Forskargrupper vid Lunds universitet,Nephrology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine,Renal physiology and peritoneal dialysis,Lund University Research Groups,Skåne University Hospital
-
(creator_code:org_t)
- 2022-01-11
- 2023
- Engelska.
-
Ingår i: Peritoneal Dialysis International. - : SAGE Publications. - 0896-8608. ; 43:1, s. 84-91
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
https://journals.sag...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Introduction: Intradialytic hypotension is a common complication of haemodialysis, but uncommon in peritoneal dialysis (PD). This may be due to lower ultrafiltration rates in PD compared to haemodialysis, allowing for sufficient refilling of the blood plasma compartment from the interstitial volume, but the underlying mechanisms are unknown. Here we assessed plasma volume and hemodynamic alterations during experimental PD with high versus low ultrafiltration rates. Methods: Experiments were conducted in two groups of healthy Sprague-Dawley rats: one group with a high ultrafiltration rate (N = 7) induced by 8.5% glucose and a low UF group (N = 6; 1.5% glucose), with an initial assessment of the extracellular fluid volume, followed by 30 min PD with plasma volume measurements at baseline, 5, 10, 15 and 30 min. Mean arterial pressure, central venous pressure and heart rate were continuously monitored during the experiment. Results: No significant changes over time in plasma volume, mean arterial pressure or central venous pressure were detected during the course of the experiments, despite an ultrafiltration (UF) rate of 56 mL/h/kg in the high UF group. In the high UF group, a decrease in extracellular fluid volume of −7 mL (−10.7% (95% confidence interval: −13.8% to −7.6%)) was observed, in line with the average UF volume of 8.0 mL (standard deviation: 0.5 mL). Conclusion: Despite high UF rates, we found that plasma volumes were remarkably preserved in the present experiments, indicating effective refilling of the plasma compartment from interstitial tissues. Further studies should clarify which mechanisms preserve the plasma volume during high UF rates in PD.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Urologi och njurmedicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Urology and Nephrology (hsv//eng)
Nyckelord
- Hypotension
- plasma volume
- ultrafiltration
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas