SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Ruetschi Ulla)
 

Sökning: WFRF:(Ruetschi Ulla) > Calibrators for Cli...

Calibrators for Clinical Measurements of Phosphorylated H2AX in Patient Cells by Flow Cytometry

Muslimovic, Aida (författare)
Gothenburg University,Göteborgs universitet,Institutionen för biomedicin, avdelningen för klinisk kemi och transfusionsmedicin,Institute of Biomedicine, Department of Clinical Chemistry and Transfusion Medicine
Johansson, Pegah, 1978 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för biomedicin, avdelningen för klinisk kemi och transfusionsmedicin,Institute of Biomedicine, Department of Clinical Chemistry and Transfusion Medicine
Rüetschi, Ulla, 1962 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för biomedicin, avdelningen för klinisk kemi och transfusionsmedicin,Institute of Biomedicine, Department of Clinical Chemistry and Transfusion Medicine
visa fler...
Hammarsten, Ola (författare)
Gothenburg University,Göteborgs universitet,Institutionen för biomedicin, avdelningen för klinisk kemi och transfusionsmedicin,Institute of Biomedicine, Department of Clinical Chemistry and Transfusion Medicine
visa färre...
 (creator_code:org_t)
Bentham Science Publishers Ltd. 2012
2012
Engelska.
Ingår i: The Open Clinical Chemistry Journal. - : Bentham Science Publishers Ltd.. - 2588-7785 .- 1874-2416. ; 5:1, s. 33-39
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Abstract: Agents that induce DNA double-strand breaks (DSBs), such as ionizing radiation, are frequently used in cancer therapy. H2AX is rapidly phosphorylated in response to DSBs and serves as a way to measure the extent of DSBs induced in patient cells. We have previously reported a flow cytometry-based method for measuring H2AX phosphorylation in pa-tient cells undergoing radiotherapy. To be able to implement measurement of H2AX phosphorylation in clinical practice, we have characterized calibrators for the flow cytometry analysis based on phosphopeptide-coated beads and fixed cells. The calibrator beads and fixed cells lost less than 11% of the signal after storage for 40 days under optimal conditions and were able to correct for day-to-day variation in method performance.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Klinisk laboratoriemedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Clinical Laboratory Medicine (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Nyckelord

H2AX
flow cytometry

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Muslimovic, Aida
Johansson, Pegah ...
Rüetschi, Ulla, ...
Hammarsten, Ola
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Klinisk laborato ...
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Cancer och onkol ...
Artiklar i publikationen
The Open Clinica ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy