Overcoming the Nyquist Limit in Blood Flow Velocity Estimation

Gudmundson, Erik (författare)
Lund University,Lunds universitet,Matematisk statistik,Matematikcentrum,Institutioner vid LTH,Lunds Tekniska Högskola,Mathematical Statistics,Centre for Mathematical Sciences,Departments at LTH,Faculty of Engineering, LTH
Jakobsson, Andreas (författare)
Lund University,Lunds universitet,Biomedical Modelling and Computation,Forskargrupper vid Lunds universitet,Statistical Signal Processing Group,Matematisk statistik,Matematikcentrum,Institutioner vid LTH,Lunds Tekniska Högskola,Lund University Research Groups,Mathematical Statistics,Centre for Mathematical Sciences,Departments at LTH,Faculty of Engineering, LTH
Gran, Fredrik (författare)
 (creator_code:org_t)
2012
2012
Engelska 4 s.
Ingår i: 2012 IEEE International Ultrasonics Symposium (IUS'12), Proceedings of. - 1948-5719. ; , s. 1615-1618
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Spectral Doppler ultrasound imaging typically consists of a spectrogram, showing the velocity distribution of the blood, and a brightness (B-) mode image allowing the operator to navigate. It is desirable to have both high spectral and velocity resolution, so that details in the blood flow can be traced, as well as a high B-mode frame rate to allow for tracking of movements and to adjust the position of the transducer. The blood flow signal is often sampled 1) using alternating transmissions for blood flow estimation and for B-mode imaging, or, 2) by acquiring a full Doppler spectrum and then parts of the B-mode image. The former has the disadvantage that it halves the sampling rate, making it likely that aliasing will occur when imaging fast moving blood or deeply positioned vessels; the latter that gaps appears in the spectrogram, and that if the frame rate of the B-mode images is slow, it will be difficult to track movements. Adaptive methods have been implemented to circumvent such problems, but even so, to get an acceptable frame rate of the B- mode images, the number of transmissions for Doppler estimation will be limited, restricting the spectral resolution. Alternatively, one may use an irregularly spaced emission pattern, but existing work on the topic is limited and generally suffers from poor resolution and spurious velocity components resulting from the irregular sampling pattern. In this paper, we examine the BIAA algorithm, showing that this approach allows for an accurate velocity estimate even from irregularly sampled measurements. Using an irregular emission pattern, with half the emissions used to form the B-mode image, the remaining emissions are found to yield accurate velocity estimates without reducing the maximally measurable velocity and without the spurious velocity components. Moreover, we show that the approach will allow for the same maximal velocity without aliasing as if all emissions would have been used for the velocity estimation.

Ämnesord

NATURVETENSKAP  -- Matematik -- Sannolikhetsteori och statistik (hsv//swe)
NATURAL SCIENCES  -- Mathematics -- Probability Theory and Statistics (hsv//eng)

Nyckelord

Nyquist limit
Irregular sampling
Doppler ultrasound

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Gudmundson, Erik
Jakobsson, Andre ...
Gran, Fredrik
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Matematik
och Sannolikhetsteor ...
Artiklar i publikationen
2012 IEEE Intern ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy