SwePub
Sök i LIBRIS databas

  Extended search

L773:0165 232X
 

Search: L773:0165 232X > Measurement of ice ...

Measurement of ice pressure on a concrete dam with a prototype ice load panel

Hellgren, Rikard, 1988- (author)
KTH,Betongbyggnad,KTH Royal Institute of Technology, Department of Civil and Architectural Engineering, Stockholm, Sweden
Malm, Richard, 1980- (author)
KTH,Betongbyggnad,KTH Royal Institute of Technology, Department of Civil and Architectural Engineering, Stockholm, Sweden
Fransson, Lennart (author)
Luleå tekniska universitet,Byggkonstruktion och brand,Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering, Luleå, Sweden
show more...
Johansson, Fredrik, 1973- (author)
KTH,Jord- och bergmekanik,KTH Royal Institute of Technology, Department of Civil and Architectural Engineering, Stockholm, Sweden
Nordström, Erik (author)
KTH Royal Institute of Technology, Department of Civil and Architectural Engineering, Stockholm, Sweden
Westberg Wilde, Marie, 1980- (author)
KTH,Jord- och bergmekanik,KTH Royal Institute of Technology, Department of Civil and Architectural Engineering, Stockholm, Sweden
show less...
 (creator_code:org_t)
Elsevier, 2020
2020
English.
In: Cold Regions Science and Technology. - : Elsevier. - 0165-232X .- 1872-7441. ; 170
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • This paper presents the development and installation of a prototype ice load panel and measurements of ice load from February 2016 to February 2018 at the Rätan hydropower dam in Sweden. The design of the 1 × 3 m2 panel enables direct measurement of ice pressure on the concrete surface is based on previous experience from similar measurements with sea ice. Important features of the design are sufficient height and width to reduce scale effects and to cover the ice thickness and variations in water level. The Rätan dam was chosen based on several criteria so that the ice load is considered to be reasonably idealized against the dam structure.For the three winters 2016, 2016/2017, 2017/2018, the maximum ice load recorded was 161 kN/m, 164 kN/m and 61 kN/m respectively. There were significant daily fluctuations during the cold winter months, and the daily peak ice loads showed a visual correlation with the daily average temperature and with the daily pattern of operation of the power station with its corresponding water level variations.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Materialteknik -- Annan materialteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Materials Engineering -- Other Materials Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Keyword

Static ice loads
Concrete dams
Dam safety
Byggmaterial
Building Materials
Structural Engineering and Bridges

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view