Optimizing Automated Peritoneal Dialysis Using an Extended 3-Pore Model

Öberg, Carl M. (författare)
Lund University,Lunds universitet,Njurfysiologi och peritonealdialys,Forskargrupper vid Lunds universitet,Renal physiology and peritoneal dialysis,Lund University Research Groups,Skåne University Hospital
Rippe, Bengt (författare)
Skåne University Hospital
 (creator_code:org_t)
Elsevier BV, 2017
2017
Engelska 9 s.
Ingår i: Kidney International Reports. - : Elsevier BV. - 2468-0249. ; 2:5, s. 943-951
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Introduction In the current study, an extended 3-pore model (TPM) is presented and applied to the problem of optimizing automated peritoneal dialysis (APD) with regard to osmotic water transport (UF), small/middle-molecule clearance, and glucose absorption. Methods Simulations were performed for either intermittent APD (IPD) or tidal APD (TPD). IPD was simulated for fill and drain volumes of 2 L, whereas TPD was simulated using a tidal volume of 0.5 L, 1 L, or 1.5 L with full drains and subsequent fills (2 L) occurring after every fifth dwell. A total of 25 cycles for a large number of different dialysate flow rates (DFR) were simulated using 3 different glucose concentrations (1.36%, 2.27%, and 3.86%) and 3 different peritoneal transport types: slow (peritoneal equilibrium test D/Pcrea < 0.6), fast (peritoneal equilibrium test D/Pcrea > 0.8), and average. Solute clearance and UF were simulated to occur during the entire dwell, including both fill and drain periods. Results It is demonstrated that DFRs exceeding ∼ 3 L/h are of little benefit both for UF and small-solute transport, whereas middle-molecule clearance is enhanced at higher DFRs. The simulations predict that large reductions (> 20%) in glucose absorption are possible by using moderately higher DFRs than a standard 6 × 2 L prescription and by using shorter optimized “bi-modal” APD regimens that alternate between a glucose-free solution and a glucose-containing solution. Discussion Reductions in glucose absorption appear to be significant with the proposed regimens for APD; however, further research is needed to assess the feasibility and safety of these regimens.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Annan medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Other Medical Engineering (hsv//eng)

Nyckelord

3-pore model
automated peritoneal dialysis
dialysis efficiency
PD prescription
urea kinetics

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Öberg, Carl M.
Rippe, Bengt
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Annan medicintek ...
Artiklar i publikationen
Kidney Internati ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy