SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Montelius L.)
 

Sökning: WFRF:(Montelius L.) > Protein depositions...

Protein depositions on one hydrocephalus shunt and on fifteen temporary ventricular catheters

Lundberg, F. (författare)
Lund University,Lunds universitet,Avdelningen för medicinsk mikrobiologi,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Medical Microbiology,Department of Laboratory Medicine,Faculty of Medicine
Tegenfeldt, J. O. (författare)
Lund University,Lunds universitet,Fasta tillståndets fysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Solid State Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Montelius, L. (författare)
Lund University,Lunds universitet,Fasta tillståndets fysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Solid State Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Ransjö, U. (författare)
Karolinska University Hospital
Appelgren, P. (författare)
Karolinska University Hospital
Siesjö, P. (författare)
Skåne University Hospital
Ljungh, Å (författare)
Lund University,Lunds universitet,Avdelningen för medicinsk mikrobiologi,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Medical Microbiology,Department of Laboratory Medicine,Faculty of Medicine
visa färre...
 (creator_code:org_t)
1997
1997
Engelska.
Ingår i: Acta Neurochirurgica. - 0001-6268. ; 139:8, s. 734-742
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Biomaterials are commonly used in modern medicine. Proteins are adsorbed to the surface of the biomaterial immediately after insertion. This report demonstrates the presence of adsorbed proteins in one infected cerebrospinal shunt from a child with hydrocephalus and on fifteen temporary ventricular catheters from adult patients with spontaneous or traumatic brain injuries. Depositions of vitronectin, fibrinogen and thrombospondin-fibronectin to some extent - on the shunt surface was imaged by field-emission scanning electron microscopy. Vitronectin, fibronectin, fibrinogen, and thrombospondin on the ventricular catheters were shown with radio-actively labelled antibodies. Furthermore, protein adsorption from human cerebrospinal fluid to heparinized and unheparinized polymers was studied under flowing conditions in vitro. On heparinized polymer, significantly reduced levels of vitronectin, fibronectin, and thrombospondin were exposed, as measured after 4 hours in vitro perfusion. After 24 hours perfusion, the differences in protein exposition between heparinized and unheparinized polymers were substantially reduced.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomaterialvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomaterials Science (hsv//eng)

Nyckelord

Protein
Shunt
Ventricular catheter

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy