SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Rääf Christopher)
 

Sökning: WFRF:(Rääf Christopher) > Maximum detection d...

Maximum detection distances for gamma emitting point sources in mobile gamma spectrometry

Finck, Robert (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Bukartas, Antanas (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Jönsson, Mattias (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
visa fler...
Rääf, Christopher (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
visa färre...
 (creator_code:org_t)
Elsevier BV, 2022
2022
Engelska.
Ingår i: Applied Radiation and Isotopes. - : Elsevier BV. - 0969-8043. ; 184
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this study an algorithm was developed for calculating maximum detectable distance (MDD) for mobile gamma-ray detection of lost sources in-situ for some common mobile spectrometer systems and gamma sources (137Cs and 60Co). The MDD is a function of detector efficiency, vehicle speed, acquisition time interval, radiation background level and accepted frequency of false alarms. To test its accuracy in predicting the MDD experiments were conducted in-situ. Results indicate agreement with experimental mobile detection distance measurements for 60Co and 137Cs point sources. Both the algorithm and the field test show that at a vehicle speed of 50 km/h, the optimal acquisition time intervals range between 3 and 10 s when searching for unshielded sources with activities of 137Cs and 60Co in the order of 100 MBq. Longer acquisition time intervals (20–30 s) are better to detect higher activity sources at the same speed. However, at higher speeds, shorter time intervals should be selected to increase the MDD. The developed algorithm can help select the optimal combination of detectors, vehicle speed, and instrument settings when using mobile searching in the event of loss of gamma-ray sources.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Detection distance
Mobile gamma spectrometry
Orphan source search

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Finck, Robert
Bukartas, Antana ...
Jönsson, Mattias
Rääf, Christophe ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Applied Radiatio ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy