SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Karacagil Sadettin)
 

Sökning: WFRF:(Karacagil Sadettin) > Renal artery stenos...

Renal artery stenosis evaluated with magnetic resonance angiography using intraarterial pressure gradient as the standard of reference : A multireader study

Eklöf, Hampus (författare)
Uppsala universitet,Enheten för radiologi
Ahlström, Håkan (författare)
Uppsala universitet,Enheten för radiologi
Boström-Ardin, A. (författare)
visa fler...
Bergqvist, David (författare)
Andrén, Bertil (författare)
Karacagil, Sadettin (författare)
Nyman, Rickard (författare)
Uppsala universitet,Enheten för radiologi
visa färre...
 (creator_code:org_t)
2016-08-30
2005
Engelska.
Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 46:8, s. 802-809
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: To evaluate 3D-Gd-magnetic resonance angiography (MRA) in detecting hemodynamically significant renal artery stenosis (RAS). MATERIAL AND METHODS: Thirty patients evaluated for atherosclerotic RAS by MRA and digital subtraction angiography (DSA) were retrospectively included. Standard of reference for hemodynamically significant RAS was a transstenotic gradient of 15 mmHg. DSA visualized 60 main renal arteries and 9 accessory arteries. Pressure gradient measurement (PGM) was available from 61 arteries. Three radiologists evaluated all examinations independently in a blinded fashion. RESULTS: RAS was present in 26 arteries. On MRA, each reader identified 4 of 9 accessory renal arteries, a detection rate of 44%. The three readers correctly classified 22/25/22 of the 26 vessels with a significant gradient as > or =60% RAS and 31/25/32 of the 35 with no significant gradient as < 60% RAS on MRA. Interobserver agreement was substantial. MRA image quality was adequate for RAS evaluations in all patients. ROC curves indicated that MRA is an adequate method for evaluating RAS. When screening for RAS, a 50% diameter reduction cut-off is better than 60%. RAS with 40-80% diameter reductions accounted for 65% of discrepancies. CONCLUSION: MRA is an adequate method for evaluating RAS limited mainly by poor detection rate for accessory renal arteries.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy