2451 0a Validity of Hip and Ankle Worn Actigraph Accelerometers for Measuring Steps as a Function of Gait Speed during Steady State Walking and Continuous Turning
264 c 2021-05-01
264 1b MDPI AG,c 2021
520 a This study aimed to investigate the accuracy and reliability of hip and ankle worn Actigraph GT3X+ (AG) accelerometers to measure steps as a function of gait speed. Additionally, the effect of the low frequency extension filter (LFEF) on the step accuracy was determined. Thirty healthy individuals walked straight and walked with continuous turns in different gait speeds. Number of steps were recorded with a hip and ankle worn AG, and with a Stepwatch (SW) activity monitor positioned around the right ankle, which was used as a reference for step count. The percentage agreement, interclass correlation coefficients and Bland–Altmann plots were determined between the AG and the reference SW across gait speeds for the two walking conditions. The ankle worn AG with the default filter was the most sensitive for step detection at >0.6 m/s, whilst accurate step detection for gait speeds < 0.6 m/s were only observed when applying the LFEF. The hip worn AG with the default filter showed poor accuracy (12–78%) at gait speeds < 1.0 m/s whereas the accuracy increased to >87% for gait speeds < 1.0 m/s when applying the LFEF. Ankle worn AG was the most sensitive to measure steps at a vast range of gait speeds. Our results suggest that sensor placement and filter settings need to be taken into account to provide accurate estimates of step counts.
700a Thurston, Cu Karolinska Institutet4 aut
700a Hagstromer, Mu Karolinska Institutet4 aut
700a Conradsson, DMu Karolinska Institutet4 aut
710a Karolinska Institutet4 org
773t Sensors (Basel, Switzerland)d : MDPI AGg 21:9q 21:9x 1424-8220
856u https://www.mdpi.com/1424-8220/21/9/3154/pdf
8564 8u http://kipublications.ki.se/Default.aspx?queryparsed=id:146614551
8564 8u https://doi.org/10.3390/s21093154

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Bezuidenhout, L
Thurston, C
Hagstromer, M
Conradsson, DM
Artiklar i publikationen
Sensors (Basel, ...
Av lärosätet
Karolinska Institutet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy