SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Nazzal Ehab M)
 

Sökning: WFRF:(Nazzal Ehab M) > Metal interference ...

Metal interference screw fixation combinations show high revision rates in primary hamstring tendon ACL reconstruction

Kaarre, Janina, 1996 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
Benvegnu, Neilen A. (författare)
Engler, Ian D. (författare)
visa fler...
Nazzal, Ehab M. (författare)
Zsidai, Balint, 1993 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
Hamrin Senorski, Eric, 1989 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för hälsa och rehabilitering,Institute of Neuroscience and Physiology, Department of Health and Rehabilitation
Musahl, Volker (författare)
Samuelsson, Kristian, 1977 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
visa färre...
 (creator_code:org_t)
2024
2024
Engelska.
Ingår i: BMC Musculoskeletal Disorders. - 1471-2474. ; 25:1
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Different fixation methods in anterior cruciate ligament reconstruction (ACLR) have been associated with different revision rates, specifically in the early postoperative period. However, most previous research has either grouped together different fixation types or evaluated femoral-sided fixation or tibial-sided fixation separately. Therefore, the purpose of this study was to determine ACL revision rates for specific combinations of femoral and tibial fixation methods within 2 years of primary hamstring tendon autograft ACLR based on data from the Swedish National Knee Ligament Registry (SNKLR). Methods: Patients that underwent primary hamstring tendon autograft ACLR between 2005 and 2018 in the SNKLR were included. The collected data included patient characteristics (age, sex, body mass index [BMI]), activity at time of injury, surgical information (concomitant injuries, time from injury to surgery, fixation types at the femur and tibia), and subsequent revision ACLR. Revision rate within 2 years of the index procedure was chosen, as ACLR fixation is most likely to contribute to ACLR revision within the first 2 years, during graft maturation. Results: Of the 23,238 included patients undergoing primary hamstring ACLR, 581 (2.5%) underwent revision ACLR within 2 years of the index procedure. Among the combinations used for > 300 patients, the femoral metal interference screw/tibial metal interference screw fixation combination had the highest revision rate followed by metal interference screw/resorbable screw and Endobutton/AO screw fixation combinations, with respective revision rates of 4.0, 3.0, and 3.0%. The lowest revision rate within 2 years of ACLR was found in the Endobutton/metal interference screw with backup Osteosuture fixation combination, used in 433 cases, with a failure rate of 0.9%. Conclusion: Different early ACL revision rates were found across different combinations of femoral and tibial fixation devices within 2 years of primary hamstring tendon autograft ACLR. Metal interference screw fixation, particularly when performed on both the femoral and tibial sides, most frequently resulted in revision ACLR. These findings may be helpful for surgeons in selecting appropriate fixation devices for hamstring ACLR. Level of evidence: IV.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Nyckelord

ACL
Anterior cruciate ligament
Reconstruction
Fixation
Hamstring tendon autograft
Revision

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy