SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Rohrer M)
 

Sökning: WFRF:(Rohrer M) > (1998-1999) > Evaluation of titan...

  • Akimoto, K (författare)

Evaluation of titanium implants placed into simulated extraction sockets : a study in dogs

  • Artikel/kapitelEngelska1999

Förlag, utgivningsår, omfång ...

  • 1999
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:hkr-13817
  • urn:nbn:se:hkr:diva-13817urn

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • The purpose of this study was to evaluate the effect of gap width on bone healing around implants placed into simulated extraction socket defects of varying widths in 10 mongrel dogs. All premolars were removed and the alveolar ridges were reduced to a width of 7 mm. Nine weeks later, a total of 80 implants, 10 mm long by 3.3 mm wide, were placed into osteotomy sites prepared to 3 different diameters in the coronal half, simulating extraction sockets. Three experimental sites, with gap sizes of 0.5 mm, 1.0 mm, and 1.4 mm, were created; the control sites had no gap. The depth of each defect was measured at the time of implant placement. All implants were stable at the time of placement. The dogs were euthanized 12 weeks after implant placement, and blocks containing the implants and adjacent bone were submitted for histologic evaluation. Clinically, all control and test sites healed, with complete bone fill in the defect. Percentages of bone-to-implant contact were measured histologically. As the gap widened, the amount of bone-to-implant contact decreased, and the point of the highest bone-to-implant contact shifted apically. These changes were statistically significant (P < .001). No statistically significant differences in bone-to-implant contact were found between the sites when the apical 4 mm of implants were compared. Within the limits of this study, the simulated extraction socket defects healed clinically, with complete bone fill, regardless of the initial gap size. However, the width of the gap at the time of implant placement had a significant impact on the histologic percentage and the height of bone-to-implant contact.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Becker, W (författare)
  • Persson, G. RutgerUniversity of Washington, Seattle, Washington(Swepub:hkr)peru (författare)
  • Baker, D A (författare)
  • Rohrer, M D (författare)
  • O'Neal, R B (författare)
  • University of Washington, Seattle, Washington (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:International Journal of Oral & Maxillofacial Implants14:3, s. 351-3600882-27861942-4434

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Akimoto, K
Becker, W
Persson, G. Rutg ...
Baker, D A
Rohrer, M D
O'Neal, R B
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
Artiklar i publikationen
International Jo ...
Av lärosätet
Högskolan Kristianstad

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy