SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Hammarström S)
 

Sökning: WFRF:(Hammarström S) > Bone tissue respons...

Bone tissue responses to Mg-incorporated oxidized implants and machine-turned implants in the rabbit femur

Sul, Young-Taeg, 1960 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för biomaterialvetenskap,Institute of Surgical Sciences, Department of Biomaterials
Hammarström Johansson, Petra, 1967 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för biomaterialvetenskap,Institute of Surgical Sciences, Department of Biomaterials
Chang, B. S. (författare)
visa fler...
Byon, E-S (författare)
Jeong, Y. (författare)
visa färre...
 (creator_code:org_t)
2005
2005
Engelska.
Ingår i: Journal of Applied Biomaterials & Biomechanics 2005. - 1724-6024. ; 3:1, s. 18-28
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Previous studies have demonstrated a significant improvement in the bone response to oxidized titanium implants. Little is known about the effects of specific oxide properties on the bone tissue responses to titanium implants. This study in-vestigated the bone tissue responses to magnesium (Mg)-incorporated oxidized titanium implants and machine-turned titani-um implants in the rabbit femur. The oxidized implants were prepared using micro arc oxidation (MAO) methods. Surface oxide properties were characterized by using various surface analytic techniques, involving scanning electron microscopy (SEM) equipped with energy dispersive spectrometer (EDS), X-ray diffractometry (XRD), X-ray photoelectron spectroscopy (XPS) and optical interferometry. Screw shaped titanium implants, 10 machine-turned implants (controls) and 10 Mg-incorporated im-plants (tests) were inserted in the femoral condyles of 10 New Zealand white rabbits. After a 6-week healing period, resonance frequency analyses and removal torque measurements of the Mg-incorporated oxidized implants demonstrated significant im-provements in implant integration with bone in comparison to machine-turned implants, p=0.007 and p=0.017, respectively. Bone growth in the pores of the oxidized implants was probably incomplete at a follow-up of 6 weeks, as indicated by SEM and EDS measurements. Mg-incorporated titanium implants significantly improved bone responses as compared with machine-turned control implants. Considering the differences and similarities of the surface oxide properties of controls and test im-plants, the enhanced bone responses to Mg-incorporated implants could be explained by the Mg surface chemistry of the test im-plants. (Journal of Applied Biomaterials & Biomechanics 2005; 3: 18-28)

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Materialteknik -- Bearbetnings-, yt- och fogningsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Materials Engineering -- Manufacturing, Surface and Joining Technology (hsv//eng)

Nyckelord

Oxidized titanium implant
Surface properties
Bone response
Magnesium surface chemistry
Resonance frequency analysis
Removal torque test

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Sul, Young-Taeg, ...
Hammarström Joha ...
Chang, B. S.
Byon, E-S
Jeong, Y.
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Materialteknik
och Bearbetnings yt ...
Artiklar i publikationen
Journal of Appli ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy