SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Matsumura M)
 

Sökning: WFRF:(Matsumura M) > Optical Coherence T...

  • Ali, Ziad A.Columbia University (författare)

Optical Coherence Tomography Characterization of Coronary Lithoplasty for Treatment of Calcified Lesions : First Description

  • Artikel/kapitelEngelska2017

Förlag, utgivningsår, omfång ...

  • Elsevier BV,2017
  • 10 s.

Nummerbeteckningar

  • LIBRIS-ID:oai:lup.lub.lu.se:efe9cc4b-6d22-49d1-9612-b692330d774f
  • https://lup.lub.lu.se/record/efe9cc4b-6d22-49d1-9612-b692330d774fURI
  • https://doi.org/10.1016/j.jcmg.2017.05.012DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:art swepub-publicationtype
  • Ämneskategori:ref swepub-contenttype

Anmärkningar

  • Objectives This study sought to determine the mechanistic effects of a novel balloon-based lithoplasty system on heavily calcified coronary lesions and subsequent stent placement using optical coherence tomography (OCT). Background The Shockwave Coronary Rx Lithoplasty System (Shockwave Medical, Fremont, California) delivers localized, lithotripsy-enhanced disruption of calcium within the target lesion (i.e., lithoplasty) for vessel preparation before stent implantation. Methods We analyzed OCT findings in 31 patients in whom lithoplasty was used to treat severely calcified stenotic coronary lesions. Results After lithoplasty, intraplaque calcium fracture was identified in 43% of lesions, with circumferential multiple fractures noted in >25%. The frequency of calcium fractures per lesion increased in the most severely calcified plaques (highest tertile vs. lowest tertile; p = 0.009), with a trend toward greater incidence of calcium fracture (77.8% vs. 22.2%; p = 0.057). Post-lithoplasty, mean acute area gain was 2.1 mm2, which further increased with stent implantation, achieving a minimal stent area of 5.94 ± 1.98 mm2 and mean stent expansion of 112.0 ± 37.2%. Deep dissections, as part of the angioplasty effect, occurred in 13% of cases and were successfully treated with stent implantation without incidence of acute closure, slow flow/no reflow, or perforation. Conclusions High-resolution imaging by OCT delineated calcium modification with fracture as a major mechanism of action of lithoplasty in vivo and demonstrated efficacy in the achievement of significant acute area gain and favorable stent expansion.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Brinton, Todd J.Stanford University Medical Center (författare)
  • Hill, Jonathan M.King's College Hospital (författare)
  • Maehara, AkikoColumbia University (författare)
  • Matsumura, MitsuakiColumbia University (författare)
  • Karimi Galougahi, KeyvanColumbia University (författare)
  • Illindala, UdayShockwave Medical Inc. (författare)
  • Götberg, MatthiasLund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine(Swepub:lu)kard-mgo (författare)
  • Whitbourn, RobertSt. Vincent's Hospital, Melbourne (författare)
  • Van Mieghem, NicolasAmsterdam UMC - Vrije Universiteit Amsterdam (författare)
  • Meredith, Ian T.Monash Medical Centre (författare)
  • Di Mario, CarloRoyal Brompton Hospital (författare)
  • Fajadet, JeanClinique Pasteur, Toulouse (författare)
  • Columbia UniversityStanford University Medical Center (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:JACC: Cardiovascular Imaging: Elsevier BV10:8, s. 897-9061936-878X

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy