SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:gup.ub.gu.se/260130"
 

Sökning: onr:"swepub:oai:gup.ub.gu.se/260130" > Blood flow, volume ...

Blood flow, volume and arterio-venous passages in induced mammary tumours of the rat

Hultborn, Ragnar, 1946 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för onkologi,Institute of Clinical Sciences, Department of Oncology
 (creator_code:org_t)
Elsevier BV, 2018
2018
Engelska.
Ingår i: Microvascular Research. - : Elsevier BV. - 0026-2862. ; 116, s. 45-49
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective To study blood flow, vascular volume and arterio-venous passages in induced mammary tumours of the rat to characterize parameters possibly responsible for tumour hyponutrition. Method Dimethylbenzanthracene-induced mammary tumours in Sprague-Dawley rats were studied. Regional blood flow was studied by use of the radioactive microsphere tracer technique using 141Cerium-labelled 15 μm spheres coinjected into the left cardiac ventricle with 125Iodine-labelled 25 μm spheres. Blood volume was studied by use of 125Iodine- or 99mTechnetium-labelled human serum albumin, the latter allowing autoradiography of tumour sections for visualization of flow and volume. Results Twenty-seven rats with 170 tumours had a mean tumour blood flow of 48 and 67 mL × min− 1 × 100 g− 1 using 15 and 25 μm sphere data, respectively, indicating a significant passage through vessels between 15 and 25 μm. The lungs showed a “nominal bronchial” blood flow of 260 and 135 mL × min− 1 × 100 g− 1 for the 15 and 25 μm spheres, respectively, indicating pulmonary trapping, particularly of small spheres passing the systemic circulation in vessels larger than 15 μm. There was a positive correlation between the total tumour blood flow within individual rats and trapped spheres of both dimensions in the lungs, indicating shunts also larger than 25 μm. Normal tissues disclosed only small differences in regional blood flow as measured by the two spheres. Blood volume was studied in 20 rats with 120 tumours, with a vascular volume of 3.6 mL × 100 g− 1 representing a blood turnover > 15 times/min. Blood volume co-localized with perfusion as seen in autoradiographs. Conclusion In induced rat mammary tumours, a high fraction of blood, 28%, passes arterio-venous vessels between 15 and 25 μm and there also exist passages > 25 μm. These findings indicate that the functional capacity of the tumour vascular bed might be impaired, adding to the abnormal microenvironment of tumours. © 2017 Elsevier Inc.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Nyckelord

Blood flow
Rat
Tumourvascular shunts
albumin
iodine 125
microsphere
microsphere ce 141
technetium 99m
albumin blood level
animal experiment
animal tissue
arteriovenous shunt
Article
blood flow velocity
blood flowmetry
blood pressure measurement
blood volume
body weight
breast tumor
controlled study
female
heart rate
heart weight
lung circulation
nonhuman
priority journal
radioactivity
systolic blood pressure
tumor blood flow
tumor growth
tumor microenvironment
tumor volume

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Hultborn, Ragnar ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Cancer och onkol ...
Artiklar i publikationen
Microvascular Re ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy