Sökning: WFRF:(Wang Chunliang) > Automatic estimatio...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 04120naa a2200565 4500 | |
001 | oai:DiVA.org:uu-502039 | |
003 | SwePub | |
008 | 230519s2023 | |||||||||||000 ||eng| | |
009 | oai:prod.swepub.kib.ki.se:152911775 | |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-5020392 URI |
024 | 7 | a https://doi.org/10.1111/aos.156982 DOI |
024 | 7 | a http://kipublications.ki.se/Default.aspx?queryparsed=id:1529117752 URI |
040 | a (SwePub)uud (SwePub)ki | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a art2 swepub-publicationtype |
100 | 1 | a Kisonaite, Konstancijau Uppsala universitet,Oftalmiatrik,Per Söderberg4 aut0 (Swepub:uu)konki863 |
245 | 1 0 | a Automatic estimation of the cross-sectional area of the waist of the nerve fiber layer at the optic nerve head |
264 | c 2023 | |
264 | 1 | b John Wiley & Sons,c 2023 |
338 | a electronic2 rdacarrier | |
520 | a PurposeGlaucoma leads to pathological loss of axons in the retinal nerve fibre layer at the optic nerve head (ONH). This study aimed to develop a strategy for the estimation of the cross-sectional area of the axons in the ONH. Furthermore, improving the estimation of the thickness of the nerve fibre layer, as compared to a method previously published by us.MethodsIn the 3D-OCT image of the ONH, the central limit of the pigment epithelium and the inner limit of the retina, respectively, were identified with deep learning algorithms. The minimal distance was estimated at equidistant angles around the circumference of the ONH. The cross-sectional area was estimated by the computational algorithm. The computational algorithm was applied on 16 non-glaucomatous subjects.ResultsThe mean cross-sectional area of the waist of the nerve fibre layer in the ONH was 1.97 ± 0.19 mm2. The mean difference in minimal thickness of the waist of the nerve fibre layer between our previous and the current strategies was estimated as CIμ (0.95) 0 ± 1 μm (d.f. = 15).ConclusionsThe developed algorithm demonstrated an undulating cross-sectional area of the nerve fibre layer at the ONH. Compared to studies using radial scans, our algorithm resulted in slightly higher values for cross-sectional area, taking the undulations of the nerve fibre layer at the ONH into account. The new algorithm for estimation of the thickness of the waist of the nerve fibre layer in the ONH yielded estimates of the same order as our previous algorithm. | |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Oftalmologi0 (SwePub)302172 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Ophthalmology0 (SwePub)302172 hsv//eng |
653 | a artificial intelligence | |
653 | a cross-sectional area | |
653 | a deep learning | |
653 | a minimal thickness | |
653 | a nerve fibre layer | |
653 | a optic nerve head | |
653 | a optical coherence tomography | |
653 | a surface area | |
653 | a waist | |
653 | a Medicinsk vetenskap | |
653 | a Medical Science | |
653 | a Ophtalmology | |
653 | a Oftalmiatrik | |
700 | 1 | a Yu, Zhaohua,d 1983-u Uppsala universitet,Oftalmiatrik4 aut0 (Swepub:uu)zhayu760 |
700 | 1 | a Raeme, Faisalu Uppsala universitet,Oftalmiatrik4 aut0 (Swepub:uu)faira396 |
700 | 1 | a Bendazzoli, Simoneu Karolinska Institutet,Kungliga Tekniska Högskolan, Medicinsk avbildning4 aut |
700 | 1 | a Wang, Chunliangu Kungliga Tekniska Högskolan, Medicinsk avbildning4 aut |
700 | 1 | a Söderberg, Per G.,d 1956-u Uppsala universitet,Oftalmiatrik4 aut0 (Swepub:uu)perso438 |
710 | 2 | a Uppsala universitetb Oftalmiatrik4 org |
773 | 0 | t Acta Ophthalmologicad : John Wiley & Sonsx 1755-375Xx 1755-3768 |
856 | 4 | u https://doi.org/10.1111/aos.15698y Fulltext |
856 | 4 | u https://uu.diva-portal.org/smash/get/diva2:1757991/FULLTEXT02.pdfx primaryx Raw objecty fulltext:print |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-502039 |
856 | 4 8 | u https://doi.org/10.1111/aos.15698 |
856 | 4 8 | u http://kipublications.ki.se/Default.aspx?queryparsed=id:152911775 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy