Sökning: WFRF:(Andersson Sören) > IDAC-CAD2VOX : A so...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 03063naa a2200349 4500 | |
001 | oai:lup.lub.lu.se:d960a37d-4eca-4b15-9313-42f84f42ebbc | |
003 | SwePub | |
008 | 190512s2017 | |||||||||||000 ||eng| | |
024 | 7 | a https://lup.lub.lu.se/record/d960a37d-4eca-4b15-9313-42f84f42ebbc2 URI |
040 | a (SwePub)lu | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a kon2 swepub-publicationtype |
072 | 7 | a ref2 swepub-contenttype |
100 | 1 | a Andersson, Martinu Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups4 aut0 (Swepub:lu)med-ma3 |
245 | 1 0 | a IDAC-CAD2VOX : A software for radiation protection calculations for the ICRP reference phantoms which are in an environment described by detailed cad drawings |
264 | 1 | c 2017 |
300 | a 4 s. | |
520 | a A computer program called IDAC-CAD2VOX has been constructed to create geometry input files from CAD drawings for the Monte Carlo simulation program MCNP. The ICRP reference phantoms are incorporated into the CAD drawings to estimate organ doses and the effective dose. The program is applied to a CAD drawing of a house and a 2D drawing of a radiation protection bunker. The created MCNP geometry was visualised by an external program Visual Editor. Dose calculations were performed for a CAD -drawing of a house, where a point source of 1 GBq 99mTc was placed in the attic. The effective dose to the adult male ICRP reference phantom was estimated to be 7.0 µSv when placed in the living room on the second floor. In summary, a method has been developed to enable effective dose estimations to adults directly from CAD files and to present the results in a pedagogic and easily understandable way. | |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng |
653 | a CAD | |
653 | a Monte Carlo simulations | |
653 | a ICRP reference phantoms | |
653 | a Effective dose | |
653 | a IDAC | |
700 | 1 | a Herrnsdorf, Larsu Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups4 aut0 (Swepub:lu)med-lsh |
700 | 1 | a Mattsson, Sörenu Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups4 aut0 (Swepub:lu)rfa-sma |
710 | 2 | a Medicinsk strålningsfysik, Malmöb Forskargrupper vid Lunds universitet4 org |
773 | 0 | t Medical Physics in the Baltic States : Proceedings of the 13th International Conference on Medical Physicsg , s. 10-13q <10-13 |
856 | 4 | u http://www.medphys.lt/medphys2017/images/MedPhys2017_Proceedings.pdfx freey FULLTEXT |
856 | 4 8 | u https://lup.lub.lu.se/record/d960a37d-4eca-4b15-9313-42f84f42ebbc |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.