SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Wang Chunliang)
 

Sökning: WFRF:(Wang Chunliang) > Diagnostic performa...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00004515naa a2200481 4500
001oai:DiVA.org:kth-318992
003SwePub
008220927s2021 | |||||||||||000 ||eng|
024a https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-3189922 URI
024a https://doi.org/10.21037/atm-21-43252 DOI
040 a (SwePub)kth
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Li, Quanu Capital Med Univ, Div Cardiol, Ctr Coronary Artery Dis, Beijing Anzhen Hosp, Beijing 100029, Peoples R China.4 aut
2451 0a Diagnostic performance of CT-derived resting distal to aortic pressure ratio (resting Pd/Pa) vs. CT-derived fractional flow reserve (CT-FFR) in coronary lesion severity assessment
264 c 2021-09
264 1b AME Publishing Company,c 2021
338 a print2 rdacarrier
500 a QC 20220927
520 a Background: Computed tomography-derived fractional flow reserve (CT-FFR) has emerged as a promising non-invasive substitute for fractional flow reserve (FFR) measurement. Normally, CT-FFR providing functional significance of coronary artery disease (CAD) by using a simplified total coronary resistance index (TCRI) model. Yet the error or discrepancy caused by this simplified model remains unclear. Methods: A total of 20 consecutive patients with suspected CAD who underwent CTA and invasive FFR measurement were retrospectively analyzed. CT-FFR and CT-(Pd/Pa)rest values derived from the coronary CTA images. The diagnostic performance of CT-FFR and CT-(Pd/Pa)rest were evaluated on a per-vessel level using C statistics with invasive FFR<0.80 as the reference standard. Results: Of the 25 vessels eventually analyzed, the prevalence of functionally significant CAD were 64%. The Youden index of the ROC curve indicated that the best cutoff value of invasive resting Pd/Pa was 0.945 for identifying functionally significant lesions. Sensitivity, specificity, negative predictive value, positive predictive value and accuracy were 85%, 91%, 92%, 83% and 88% for CT-(Pd/Pa)rest and 85%, 58% 69%, 78% and 72% for CT-FFR. Area under the receiver-operating characteristic curve (AUC) to detect functionally significant stenoses of CT-(Pd/Pa)rest and CT-FFR were 0.87 and 0.90. Conclusions: In this study, the results suggest CT-derived resting Pd/Pa has a potential advantage over CT-FFR in triaging patients for revascularization.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Kardiologi0 (SwePub)302062 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Cardiac and Cardiovascular Systems0 (SwePub)302062 hsv//eng
650 7a MEDICIN OCH HÄLSOVETENSKAPx Medicinska och farmaceutiska grundvetenskaperx Cell- och molekylärbiologi0 (SwePub)301082 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Basic Medicinex Cell and Molecular Biology0 (SwePub)301082 hsv//eng
650 7a MEDICIN OCH HÄLSOVETENSKAPx Medicinska och farmaceutiska grundvetenskaperx Fysiologi0 (SwePub)301062 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Basic Medicinex Physiology0 (SwePub)301062 hsv//eng
653 a Fractional flow reserve (FFR)
653 a computational fluid dynamics
653 a coronary CT angiography
653 a pressure ratio
700a Zhang, Yangu Capital Med Univ, Div Cardiol, Ctr Coronary Artery Dis, Beijing Anzhen Hosp, Beijing 100029, Peoples R China.4 aut
700a Wang, Chunliang,d 1980-u KTH,Medicinsk avbildning,Shenzhen Escope Tech Inc, Shenzhen, Peoples R China.4 aut0 (Swepub:kth)u1tbkeej
700a Dong, Shimingu Second Mil Med Univ, Changzheng Hosp, Dept Cardiol, Shanghai, Peoples R China.4 aut
700a Mao, Yijinu Shenzhen Escope Tech Inc, Shenzhen, Peoples R China.4 aut
700a Tang, Yidau Peking Univ Third Hosp, Dept Cardiovasc Med, Beijing 100191, Peoples R China.4 aut
700a Zeng, Yongu Capital Med Univ, Div Cardiol, Ctr Coronary Artery Dis, Beijing Anzhen Hosp, Beijing 100029, Peoples R China.4 aut
710a Capital Med Univ, Div Cardiol, Ctr Coronary Artery Dis, Beijing Anzhen Hosp, Beijing 100029, Peoples R China.b Medicinsk avbildning4 org
773t Annals of Translational Medicined : AME Publishing Companyg 9:17q 9:17x 2305-5839x 2305-5847
856u https://atm.amegroups.com/article/viewFile/78877/pdf
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-318992
8564 8u https://doi.org/10.21037/atm-21-4325

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy