SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Åstrand Anders)
 

Search: WFRF:(Åstrand Anders) > Contact angle and i...

Contact angle and indentation velocity dependency for a resonance sensor : Evaluation on soft tissue silicone models

Åstrand, Anders (author)
Umeå universitet,Institutionen för tillämpad fysik och elektronik,Centrum för medicinsk teknik och fysik (CMTF)
Jalkanen, Ville (author)
Umeå universitet,Institutionen för tillämpad fysik och elektronik,Centrum för medicinsk teknik och fysik (CMTF)
Andersson, Britt M. (author)
Umeå universitet,Institutionen för tillämpad fysik och elektronik,Centrum för medicinsk teknik och fysik (CMTF)
show more...
Lindahl, Olof A. (author)
Umeå universitet,Institutionen för strålningsvetenskaper,Centrum för medicinsk teknik och fysik (CMTF)
show less...
 (creator_code:org_t)
2013-04-03
2013
English.
In: Journal of Medical Engineering & Technology. - : Informa Healthcare. - 0309-1902 .- 1464-522X. ; 37:3, s. 185-196
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Human tissue stiffness can vary due to different tissue conditions such as cancer tumours. Earlier studies show that stiffness may be detected with a resonance sensor that measures frequency shift and contact force at application. Through the frequency shift and the contact force, a tissue stiffness parameter can be derived. This study evaluated how the probe application angle and indentation velocity affected the results and determined the maximum parameter errors. The evaluation was made on flat silicone discs with specified hardness. The frequency shift, the force and the stiffness parameter all varied with contact angle and indentation velocity. A contact angle of ≤10° was acceptable for reliable measurements. A low indentation velocity was recommended. The maximum errors for the system were <1.1% of the measured values. It was concluded that contact angle and indentation velocity have to be considered in the clinical setting. The angular dependency is especially important in clinical use for studying stiffness of human soft tissue, e.g. in prostate cancer diagnosis.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)

Keyword

Contact angle
Frequency shift
Indentation velocity
Resonance sensor
Tissue stiffness

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Åstrand, Anders
Jalkanen, Ville
Andersson, Britt ...
Lindahl, Olof A.
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
Articles in the publication
Journal of Medic ...
By the university
Umeå University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view