SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Campo E.)
 

Sökning: WFRF:(Campo E.) > Calibration of ther...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003884naa a2200649 4500
001oai:DiVA.org:ri-51496
003SwePub
008210111s2020 | |||||||||||000 ||eng|
024a https://urn.kb.se/resolve?urn=urn:nbn:se:ri:diva-514962 URI
024a https://doi.org/10.1088/0026-1394/57/1A/030062 DOI
040 a (SwePub)ri
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Del Campo, D.u CEM, Spain4 aut
2451 0a Calibration of thermocouples from 419,527 °C (freezing point of Zn) up to 1492 °C (melting point of the Pd-C eutectic), by the temperature fixed point and comparison methods
264 1b IOP Publishing Ltd,c 2020
338 a print2 rdacarrier
520 a This report present the results of the EURAMET inter-comparison carried out to compare the calibration of thermocouples from 419,527 °C (freezing point of Zn) up to 1492 °C (melting point of the Pd-C eutectic). This inter-comparison is intended to be used to support the calibration and measurement capabilities (CMCs) of the participants in the calibration of thermocouples. The comparison was organized in three loops with nineteen participating laboratories and it allowed the performance of the measurement either in fixed points and/or by comparison. The method used to analyse the results of the comparison was the generalized weighted mean that takes into account the full covariance matrix that includes correlations between the participants which have similar traceability sources and between measurements performed by the same laboratory (i.e. the pilots that performed measurements at the beginning and at the end of each loop and the measurements performed by the same laboratory in fixed points and by comparison at the same calibration point). Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA). 
653 a Calibration
653 a Covariance matrix
653 a Eutectics
653 a Freezing
653 a Melting point
653 a Thermocouples
653 a Calibration and measurement capabilities
653 a Calibration points
653 a Comparison methods
653 a Freezing point
653 a Intercomparisons
653 a Key comparison database
653 a Mutual recognition arrangements
653 a Temperature-fixed point
653 a Palladium compounds
700a Abdelaziz, Y.u NIS, Egypt4 aut
700a Anagnostou, M.u EIM, Greece4 aut
700a Arifovic, N.u TUBITAK UME, Turkey4 aut
700a Bergerud, R. A.u JV, Norway4 aut
700a Bojkovski, J.u MIRS/UL-FE/LMK, Slovenia4 aut
700a Ciocarlan, E.u INM, Romania4 aut
700a Edler, F.u PTB, Germany4 aut
700a Elliot, C.u NPL, UK4 aut
700a Hathela, O.u MIKES, Finland4 aut
700a Hodzic, N.u IMBiH, Bosnia and Herzegovina4 aut
700a Holmsten, Magnusu RISE,Mätteknik4 aut
700a Iacomini, L.u INRIM, Italy4 aut
700a Kozicki, M.u GUM, Poland4 aut
700a Nedialkov, S.u BIM, Bulgaria4 aut
700a Sadli, M.u CNAM, France4 aut
700a Simic, S.u DMDM, Serbia4 aut
700a Strnad, R.u CMI, Czech Republic4 aut
700a Turzó-András, E.u BFKH, Hungary4 aut
710a CEM, Spainb NIS, Egypt4 org
773t Metrologiad : IOP Publishing Ltdg 57:1 A, s. 1-121q 57:1 A<1-121x 0026-1394x 1681-7575
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:ri:diva-51496
8564 8u https://doi.org/10.1088/0026-1394/57/1A/03006

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy