SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Dance David R)
 

Search: WFRF:(Dance David R) > (2000-2004) > Distributions of sc...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003095nam a2200349 4500
001oai:DiVA.org:liu-57875
003SwePub
008100702s2004 | |||||||||||000 ||eng|
024a https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-578752 URI
040 a (SwePub)liu
041 a engb eng
042 9 SwePub
072 7a vet2 swepub-contenttype
072 7a rap2 swepub-publicationtype
100a Ullman, Gustavu Linköpings universitet,Radiofysik,Hälsouniversitetet4 aut0 (Swepub:liu)gusul07
2451 0a Distributions of scatter-to-primary ratios in chest PA radiography using grid or air gap for scatter-rejection
264 1a Linköping :b Linköping University Electronic Press,c 2004
300 a 39 s.
338 a electronic2 rdacarrier
490a Report / Institutionen för radiofysik, Universitetet i Linköping, 1998- ;v 100
520 a The aim for this work was to calculate distributions of scatter-to-primary ratios (εs/εp) and signal-to-noise ratios per pixel (SNRp) for a large set of imaging systems with either grid or air gap for scatter rejection. Grids with ratio 8-16 and air gap length 20 and 40 cm were used. The tube voltage was varied between 90-150 kV and three patient thickness between 20-28 cm were tested in order to compare scatter-rejections techniques for different conditions. Distributions of this sort may provide useful information on how physical image quality (contrast, SNR) is distributed over the chest PA image. A Monte Carlo computer program was used for the calculations, including a model of both the patient (voxel phantom) and the imaging system. The mean value of the εs/εp is 0.39 in the hilar region and 1.72 in the lower mediastinal region. For a 28 cm patient, the corresponding values are 0.42 in the hilar region and 2.58 in the lower mediastinal region. The grid with ratio 16 is the most efficient scatter rejection technique in all regions except the hilar region. In the hilar region, the most efficient technique is the 40 cm air gap.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng
653 a Radiological physics
653 a Radiofysik
700a Sandborg, Michaelu Östergötlands Läns Landsting,Linköpings universitet,Radiofysik,Hälsouniversitetet,Radiofysikavdelningen4 aut0 (Swepub:liu)micsa02
700a Dance, David Ru Department of Physics, The Royal Marsden NHS Trust, UK4 aut
700a Hunt, Rogeru Department of Physics, The Royal Marsden NHS Trust, UK4 aut
700a Alm Carlsson, Gudrunu Östergötlands Läns Landsting,Linköpings universitet,Radiofysik,Hälsouniversitetet,Radiofysikavdelningen4 aut0 (Swepub:liu)gudal03
710a Linköpings universitetb Radiofysik4 org
856u https://liu.diva-portal.org/smash/get/diva2:328214/FULLTEXT01.pdfx primaryx Raw objecty fulltext
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-57875

To the university's database

Find more in SwePub

By the author/editor
Ullman, Gustav
Sandborg, Michae ...
Dance, David R
Hunt, Roger
Alm Carlsson, Gu ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Parts in the series
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view