245 | 1 0 | a Bone Conduction Stimulated VEMP Using the B250 Transducer |
264 | 1 | c 2021 |
338 | a electronic2 rdacarrier | |
520 | a Objective: Bone conduction (BC) stimulation is rarely used for clinical testing of vestibular evoked myogenic potentials (VEMPs) due to the limitations of conventional stimulation alternatives. The aim of this study is to compare VEMP using the new B250 transducer with the Minishaker and air conduction (AC) stimulation. Methods: Thirty normal subjects between 20 and 37 years old and equal gender distribution were recruited, 15 for ocular VEMP and 15 for cervical VEMP. Four stimulation conditions were compared: B250 on the mastoid (FM); Minishaker and B250 on the forehead (FZ); and AC stimulation using an insert earphone. Results: It was found that B250 at FM required a statistically significant lower hearing level than with AC stimulation, in average 41 dB and 35 dB lower for ocular VEMP and cervical VEMP, respectively, but gave longer n10 (1.1 ms) and n23 (1.6 ms). No statistical difference was found between B250 at FM and Minishaker at FZ. Conclusion: VEMP stimulated with B250 at FM gave similar response as the Minishaker at FZ and for a much lower hearing level than AC stimulation using insert earphones. | |
650 | 7 | a TEKNIK OCH TEKNOLOGIERx Medicinteknikx Annan medicinteknik0 (SwePub)206992 hsv//swe |
650 | 7 | a ENGINEERING AND TECHNOLOGYx Medical Engineeringx Other Medical Engineering0 (SwePub)206992 hsv//eng |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Oto-rhino-laryngologi0 (SwePub)302182 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Otorhinolaryngology0 (SwePub)302182 hsv//eng |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Medicinska och farmaceutiska grundvetenskaperx Farmakologi och toxikologi0 (SwePub)301022 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Basic Medicinex Pharmacology and Toxicology0 (SwePub)301022 hsv//eng |
653 | a vestibular evoked myogenic potential | |
653 | a bone conduction | |
653 | a B250 | |
700 | 1 | a Håkansson, Bo,d 1953u Chalmers tekniska högskola,Chalmers University of Technology4 aut0 (Swepub:cth)boh |
700 | 1 | a Reinfeldt, Sabine,d 1978u Chalmers tekniska högskola,Chalmers University of Technology4 aut0 (Swepub:cth)f97sare |
700 | 1 | a Persson, Ann-Charlotteu Göteborgs universitet,University of Gothenburg4 aut |
700 | 1 | a Eeg-Olofsson, Mansu Göteborgs universitet,University of Gothenburg4 aut |
710 | 2 | a Chalmers tekniska högskolab Göteborgs universitet4 org |
773 | 0 | t Medical Devices: Evidence and Researchg 14, s. 225-237q 14<225-237x 1179-1470 |
856 | 4 | u https://research.chalmers.se/publication/524983/file/524983_Fulltext.pdfx primaryx freey FULLTEXT |
856 | 4 8 | u https://research.chalmers.se/publication/524983 |
856 | 4 8 | u https://doi.org/10.2147/MDER.S317072 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy