Diabetes Antibody Standardization Program: evaluation of assays for insulin autoantibodies

Schlosser, M. (författare)
Mueller, P. W. (författare)
Törn, Carina (författare)
Lund University,Lunds universitet,Celiaki och diabetes,Forskargrupper vid Lunds universitet,Celiac Disease and Diabetes Unit,Lund University Research Groups
visa fler...
Bonifacio, E. (författare)
Bingley, P. J. (författare)
visa färre...
 (creator_code:org_t)
2010-09-25
2010
Engelska.
Ingår i: Diabetologia. - : Springer Science and Business Media LLC. - 1432-0428 .- 0012-186X. ; 53:12, s. 2611-2620
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Aims/hypothesis Insulin autoantibodies (IAA) are important in type I diabetes risk assessment. However, their determination varies more between laboratories than other diabetes autoantibodies. The Diabetes Antibody Standardization Program (DASP) aims to improve and standardise measurement of autoantibodies associated with type I diabetes. We report the results of measurement of IAA from DASP workshops in 2002, 2003 and 2005. Methods Up to 32 laboratories in 14 countries participated in each workshop. Aliquots of coded sera from 50 patients with newly diagnosed type I diabetes and 100 blood donor controls were circulated to participating laboratories. Reported results were analysed using receiver operator characteristic (ROC) curves. We compared concordance of antibody levels by ranking, IAA and insulin antibody (IA) indices and units derived from an IA standard curve. Results In all three workshops IAA assay performance had improved compared with DASP 2000. The median area under the ROC curve was 0.73 in DASP 2002, 0.78 in 2003 and 0.80 in 2005 (p=0.0012), and median laboratory-assigned sensitivity was 26% in 2002, 36% in 2003 and 45% in 2005 (p<0.0001). There was, however, marked variation between assays. The range of AUC was 0.36-0.91 and that of laboratory-assigned sensitivity was 22-57%. Concordance of ranking of patient serum samples was related to AUC (p<0.001). Using an index related to common IAA and IA-positive or -negative control sera improved the concordance between assays (p<0.0001). Conclusions/interpretation The overall performance of IAA assays has improved but there is still wide variation between laboratories. Concordance between assays would be improved by the use of a common reference reagent.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Endokrinologi och diabetes (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Endocrinology and Diabetes (hsv//eng)

Nyckelord

Reference serum
Sensitivity
Specificity
Prediction
Islet autoantibodies
index
Insulin autoantibody
Insulin autoantibodies
Adjusted sensitivity
AUC

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Schlosser, M.
Mueller, P. W.
Törn, Carina
Bonifacio, E.
Bingley, P. J.
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Endokrinologi oc ...
Artiklar i publikationen
Diabetologia
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy