SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Engvall Jan)
 

Search: WFRF:(Engvall Jan) > Magnetic Resonance ...

Magnetic Resonance Imaging of the Heart : Image quality, measurement accuracy and patient experience

Ahlander, Britt-Marie, 1954- (author)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten
Engvall, Jan, Professor (thesis advisor)
Linköpings universitet,Avdelningen för kardiovaskulär medicin,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinska fakulteten,Region Östergötland, Fysiologiska kliniken US
Ericsson, Elisabeth, docent, 1959- (thesis advisor)
Örebro universitet, Institutionen för hälsovetenskaper,Institutionen för hälsovetenskaper, Örebro universitet
show more...
Maret, Eva, Med. Dr. (thesis advisor)
Institutionen för laboratoriemedicin, Karolinska institutet, Stockholm
Carlsson, Marcus, Docent (opponent)
Klinisk Fysiologi, Skånes Universitetssjukhus, Lund
show less...
 (creator_code:org_t)
ISBN 9789176857427
Linköping : Linköping University Electronic Press, 2016
English 74 s.
Series: Linköping University Medical Dissertations, 0345-0082 ; 1524
  • Doctoral thesis (other academic/artistic)
Abstract Subject headings
Close  
  • Background: Non-invasive diagnostic imaging of atherosclerotic coronary artery disease (CAD) is frequently carried out with cardiovascular magnetic resonance imaging (CMR) or myocardial perfusion single photon emission computed tomography (MPS). CMR is the gold standard for the evaluation of scar after myocardial infarction and MPS the clinical gold standard for ischemia. Magnetic Resonance Imaging (MRI) is at times difficult for patients and may induce anxiety while patient experience of MPS is largely unknown.Aims: To evaluate image quality in CMR with respect to the sequences employed, the influence of atrial fibrillation, myocardial perfusion and the impact of patient information. Further, to study patient experience in relation to MRI with the goal of improving the care of these patients.Method: Four study designs have been used. In paper I, experimental cross-over, paper (II) experimental controlled clinical trial, paper (III) psychometric crosssectional study and paper (IV) prospective intervention study. A total of 475 patients ≥ 18 years with primarily cardiac problems (I-IV) except for those referred for MRI of the spine (III) were included in the four studies.Result: In patients (n=20) with atrial fibrillation, a single shot steady state free precession (SS-SSFP) sequence showed significantly better image quality than the standard segmented inversion recovery fast gradient echo (IR-FGRE) sequence (I). In first-pass perfusion imaging the gradient echo-echo planar imaging sequence (GREEPI) (n=30) had lower signal-to-noise and contrast–to-noise ratios than the steady state free precession sequence (SSFP) (n=30) but displayed a higher correlation with the MPS results, evaluated both qualitatively and quantitatively (II). The MRIAnxiety Questionnaire (MRI-AQ) was validated on patients, referred for MRI of either the spine (n=193) or the heart (n=54). The final instrument had 15 items divided in two factors regarding Anxiety and Relaxation. The instrument was found to have satisfactory psychometric properties (III). Patients who prior CMR viewed an information video scored significantly (lower) better in the factor Relaxation, than those who received standard information. Patients who underwent MPS scored lower on both factors, Anxiety and Relaxation. The extra video information had no effect on CMR image quality (IV).Conclusion: Single shot imaging in atrial fibrillation produced images with less artefact than a segmented sequence. In first-pass perfusion imaging, the sequence GRE-EPI was superior to SSFP. A questionnaire depicting anxiety during MRI showed that video information prior to imaging helped patients relax but did not result in an improvement in image quality.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Allmänmedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- General Practice (hsv//eng)

Keyword

Medicine
Medicin

Publication and Content Type

vet (subject category)
dok (subject category)

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view