SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0001 6314
 

Sökning: L773:0001 6314 > (2010-2014) > A virtual reality t...

A virtual reality test battery for assessment and screening of spatial neglect

Fordell, Helena (författare)
Umeå universitet,Klinisk neurovetenskap
Bodin, Kenneth (författare)
Umeå universitet,Högpresterande beräkningscentrum norr (HPC2N),UMIT
Bucht, Gustaf (författare)
Umeå universitet,Geriatrik
visa fler...
Malm, Jan (författare)
Umeå universitet,Klinisk neurovetenskap
visa färre...
 (creator_code:org_t)
2011-01-27
2011
Engelska.
Ingår i: Acta Neurologica Scandinavica. - : John Wiley & Sons. - 0001-6314 .- 1600-0404. ; 123:3, s. 167-174
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background – There is a need for improved screening methods for spatial neglect.Aim – To construct a VR-test battery and evaluate its accuracy and usability in patients with acute stroke.Method –  VR-DiSTRO consists of a standard desktop computer, a CRT monitor and eye shutter stereoscopic glasses, a force feedback interface, and software, developed to create an interactive and immersive 3D experience. VR-tests were developed and validated to the conventional Star Cancellation test, Line bisection, Baking Tray Task (BTT), and Visual Extinction test. A construct validation to The Rivermead Behavioral Inattention Test, used as criterion of visuospatial neglect, was made. Usability was assessed according to ISO 9241-11.Results –  Thirty-one patients with stroke were included, 9/31 patients had neglect. The sensitivity was 100% and the specificity 82% for the VR-DiSTRO to correctly identify neglect. VR-BTT and VR-Extinction had the highest correlation (r2 = 0.64 and 0.78), as well as high sensitivity and specificity. The kappa values describing the agreement between traditional neglect tests and the corresponding virtual reality test were between 0.47–0.85. Usability was assessed by a questionnaire; 77% reported that the VR-DiSTRO was ‘easy’ to use. Eighty-eight percent reported that they felt ‘focused’, ‘pleased’ or ‘alert’. No patient had adverse symptoms. The test session took 15 min.Conclusions –  The VR-DiSTRO quickly and with a high accuracy identified visuospatial neglect in patients with stroke in this construct validation. The usability among elderly patients with stroke was high. This VR-test battery has the potential to become an important screening instrument for neglect and a valuable adjunct to the neuropsychological assessment.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Neurologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Neurology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Annan medicin och hälsovetenskap -- Övrig annan medicin och hälsovetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Other Medical and Health Sciences -- Other Medical and Health Sciences not elsewhere specified (hsv//eng)

Nyckelord

perceptual disorder
hemispatial neglect
diagnosis
neuro psychological tests
task performance and analysis
visual perception
user computer interface
stroke complications
assessment

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Fordell, Helena
Bodin, Kenneth
Bucht, Gustaf
Malm, Jan
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Neurologi
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Annan medicin oc ...
och Övrig annan medi ...
Artiklar i publikationen
Acta Neurologica ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy