A virtual reality test battery for assessment and screening of spatial neglect

Fordell, Helena (author)
Umeå universitet,Klinisk neurovetenskap
Bodin, Kenneth (author)
Umeå universitet,Högpresterande beräkningscentrum norr (HPC2N),UMIT
Bucht, Gustaf (author)
Umeå universitet,Geriatrik
show more...
Malm, Jan (author)
Umeå universitet,Klinisk neurovetenskap
show less...
 (creator_code:org_t)
2011-01-27
2011
English.
In: Acta Neurologica Scandinavica. - : John Wiley & Sons. - 0001-6314 .- 1600-0404. ; 123:3, s. 167-174
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Background – There is a need for improved screening methods for spatial neglect.Aim – To construct a VR-test battery and evaluate its accuracy and usability in patients with acute stroke.Method –  VR-DiSTRO consists of a standard desktop computer, a CRT monitor and eye shutter stereoscopic glasses, a force feedback interface, and software, developed to create an interactive and immersive 3D experience. VR-tests were developed and validated to the conventional Star Cancellation test, Line bisection, Baking Tray Task (BTT), and Visual Extinction test. A construct validation to The Rivermead Behavioral Inattention Test, used as criterion of visuospatial neglect, was made. Usability was assessed according to ISO 9241-11.Results –  Thirty-one patients with stroke were included, 9/31 patients had neglect. The sensitivity was 100% and the specificity 82% for the VR-DiSTRO to correctly identify neglect. VR-BTT and VR-Extinction had the highest correlation (r2 = 0.64 and 0.78), as well as high sensitivity and specificity. The kappa values describing the agreement between traditional neglect tests and the corresponding virtual reality test were between 0.47–0.85. Usability was assessed by a questionnaire; 77% reported that the VR-DiSTRO was ‘easy’ to use. Eighty-eight percent reported that they felt ‘focused’, ‘pleased’ or ‘alert’. No patient had adverse symptoms. The test session took 15 min.Conclusions –  The VR-DiSTRO quickly and with a high accuracy identified visuospatial neglect in patients with stroke in this construct validation. The usability among elderly patients with stroke was high. This VR-test battery has the potential to become an important screening instrument for neglect and a valuable adjunct to the neuropsychological assessment.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Neurologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Neurology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Annan medicin och hälsovetenskap -- Övrig annan medicin och hälsovetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Other Medical and Health Sciences -- Other Medical and Health Sciences not elsewhere specified (hsv//eng)

Keyword

perceptual disorder
hemispatial neglect
diagnosis
neuro psychological tests
task performance and analysis
visual perception
user computer interface
stroke complications
assessment

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Fordell, Helena
Bodin, Kenneth
Bucht, Gustaf
Malm, Jan
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Neurology
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Other Medical an ...
and Other Medical an ...
Articles in the publication
Acta Neurologica ...
By the university
Umeå University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view