Sökning: WFRF:(Olofsson Thomas) > Application of Inte...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 03074naa a2200409 4500 | |
001 | oai:DiVA.org:umu-175779 | |
003 | SwePub | |
008 | 201008s2020 | |||||||||||000 ||eng| | |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-1757792 URI |
024 | 7 | a https://doi.org/10.1016/j.buildenv.2020.1073552 DOI |
040 | a (SwePub)umu | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a art2 swepub-publicationtype |
100 | 1 | a Azizi, Shoaibu Umeå universitet,Institutionen för tillämpad fysik och elektronik,Energy efficiency4 aut0 (Swepub:umu)shaz0006 |
245 | 1 0 | a Application of Internet of Things in academic buildings for space use efficiency using occupancy and booking data |
264 | 1 | b Elsevier,c 2020 |
338 | a electronic2 rdacarrier | |
520 | a Environmental sustainability in academic buildings can be improved with management interventions such as improving space use efficiency supported by large data from the Internet of Things (IoT). Due to the potentials, the interest in the use of IoT tools for facility management is high among universities. However, empirical studies on this topic are scarce. To address the knowledge gap in this area, this study proposes and examines a process model with steps to measure space use and to improve space use efficiency by IoT tools in academic buildings. The applicability of the model is investigated in 8 lecture halls in a university building by using occupancy and booking data from IoT tools. Four space use indicators are developed to visualize the data and quantify space use, and based on them, the strategies and interventions for space use efficiency are proposed and discussed. | |
650 | 7 | a TEKNIK OCH TEKNOLOGIERx Maskinteknikx Energiteknik0 (SwePub)203042 hsv//swe |
650 | 7 | a ENGINEERING AND TECHNOLOGYx Mechanical Engineeringx Energy Engineering0 (SwePub)203042 hsv//eng |
653 | a Space use monitoring | |
653 | a Data-driven facility management | |
653 | a Smart campus | |
653 | a Occupancy detection | |
653 | a Energy saving | |
700 | 1 | a Nair, Gireeshu Umeå universitet,Institutionen för tillämpad fysik och elektronik,Energy efficiency4 aut0 (Swepub:umu)gigo0003 |
700 | 1 | a Rabiee, Ramtinu Umeå universitet,Institutionen för tillämpad fysik och elektronik4 aut0 (Swepub:umu)rara0313 |
700 | 1 | a Olofsson, Thomas,d 1968-u Umeå universitet,Institutionen för tillämpad fysik och elektronik,Energy efficiency4 aut0 (Swepub:umu)thol0001 |
710 | 2 | a Umeå universitetb Institutionen för tillämpad fysik och elektronik4 org |
773 | 0 | t Building and Environmentd : Elsevierg 186q 186x 0360-1323x 1873-684X |
856 | 4 | u https://doi.org/10.1016/j.buildenv.2020.107355y Fulltext |
856 | 4 | u https://umu.diva-portal.org/smash/get/diva2:1474565/FULLTEXT01.pdfx primaryx Raw objecty fulltext:print |
856 | 4 | u https://doi.org/10.1016/j.buildenv.2020.107355 |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-175779 |
856 | 4 8 | u https://doi.org/10.1016/j.buildenv.2020.107355 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.