SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0090 6964 OR L773:1573 9686
 

Sökning: L773:0090 6964 OR L773:1573 9686 > A Pull-Back Algorit...

A Pull-Back Algorithm to Determine the Unloaded Vascular Geometry in Anisotropic Hyperelastic AAA Passive Mechanics

Riveros, Fabian (författare)
Chandra, Santanu (författare)
Finol, Ender A. (författare)
visa fler...
Gasser, T. Christian (författare)
KTH,Hållfasthetslära (Inst.)
Rodriguez, Jose F. (författare)
visa färre...
KTH Hållfasthetslära (Inst(creator_code:org_t)
2012-11-29
2013
Engelska.
Ingår i: Annals of Biomedical Engineering. - : Springer Science and Business Media LLC. - 0090-6964 .- 1573-9686. ; 41:4, s. 694-708
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Biomechanical studies on abdominal aortic aneurysms (AAA) seek to provide for better decision criteria to undergo surgical intervention for AAA repair. More accurate results can be obtained by using appropriate material models for the tissues along with accurate geometric models and more realistic boundary conditions for the lesion. However, patient-specific AAA models are generated from gated medical images in which the artery is under pressure. Therefore, identification of the AAA zero pressure geometry would allow for a more realistic estimate of the aneurysmal wall mechanics. This study proposes a novel iterative algorithm to find the zero pressure geometry of patient-specific AAA models. The methodology allows considering the anisotropic hyperelastic behavior of the aortic wall, its thickness and accounts for the presence of the intraluminal thrombus. Results on 12 patient-specific AAA geometric models indicate that the procedure is computational tractable and efficient, and preserves the global volume of the model. In addition, a comparison of the peak wall stress computed with the zero pressure and CT-based geometries during systole indicates that computations using CT-based geometric models underestimate the peak wall stress by 59 +/- A 64 and 47 +/- A 64 kPa for the isotropic and anisotropic material models of the arterial wall, respectively.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology (hsv//eng)

Nyckelord

Abdominal aortic aneurysm (AAA)
Patient-specific
Image-based
Zero pressure geometry
FEA
Anisotropy

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy